Download Print this page

Film-Tech IREM EX-100GM3 Series Installation And Operation Manual page 21

Electronic

Advertisement

Functions and controls
Synoptic panel
When switching on the unit, the synoptic panel will display:
1) FIRMWARE: the firmware identification is recognizable through the characters V.xx.y.
displayed on the synoptic panel for 5-6 seconds after switching on (xx stands for ver-
sion, while y for release).
2) DISPLAY mode
This mode is highlighted by the coming on of the following LEDs on the synoptic
panel:
. LINE LED
. MAN LED
Keys:
to decrease the current value (active under manual operation from
synoptic panel only)
to increase the current value (active under manual operation from
synoptic panel only)
inverter ON/OFF (active under manual operation from
synoptic panel only)
enables the output current
This key is helpful to display:
. output current
. output power (not displayed if the lamp has been turned off)
. output voltage (not displayed if the lamp has been turned off)
. unit operating temperature (not displayed if the lamp has been turned off)
. lamp operating hours
Pressing the key "left" or "right", the displaying of "current setting" or "current output"
will be activated, independently from the parameters currently on.
MAN01554E/1
20

Advertisement

loading

This manual is also suitable for:

Irem ex-100gm3-usIrem ex-100gm3-e