Connection and operating information
Parameter setting
For more detailed information, please refer to EX communication protocol on
sections: "programming the lamp parameters" and "behaviour to wrong lamp
parameters sent to bytes m.s.b. command data (dh) and dato l.s.b. command
data (dl) via RS232".
Lamp P
: max. power of the lamp. When entered, an automatic control will avoid
max
exceeding this value. Factory setting: 3400W (corresponding to the max. power of the
power supply).
Lamp I
(operating range: 30 - 110A): lamp max. admitted current. When entered,
max
an automatic control will avoid exceeding this value. Factory setting: 110A
When entering an I
max
Lamp I
(operating range: 30 - 65A): lamp min. admitted current. When entered, an
min
automatic control will avoid exceeding this value. Factory setting: 30A
Lamp stand-by (operating range: I
11 and 12 of J4 have been closed. When the contacts have been closed, an automatic
control will change the current according to the admitted operating range. Factory
setting: 30A.
The stand-by mode can be also activated through the serial line.
Factory setting of the output current: 30A.
Remarks:
1) when entering an I
max
value not accepted" will be displayed. I
value.
2) when entering a min. value exceeding 65A, 30A will be set as default value.
MAN01554E/1
value lower than I
, I
min
min
- I
): lamp stand-by current when the contacts
max
min
value lower than I
min
will be set to 30A (default). Enter a new I
min
17
will be the delivered current value.
the message "ERROR, Imax < Imin -