7.5 Telecomando

Istruzioni per il montaggio e l'installazione
In caso di utilizzo con un fancoil master assicurarsi che sia stata inserita la resistenza
tra i morsetti GN e V+ (del fancoil) e che sia stata collegata la scheda ricevitore
HYIR******.
Avvertenze
Togliere l'alimentazione prima di effettuare tutte le operazioni di installazione e
manutenzione sul fancoil.
Adottare precauzioni contro le scariche elettrostatiche nel maneggiare la scheda
fancoil.
Caratteristiche tecniche
Alimentazione
Due batterie da 1,5V mini-stilo.
Condizioni di stoccaggio
-20T80 °C, umidità 80% U.R. non condensante
Condizioni di funzionamento
0T60 °C, umidità <90% U.R. non condensante
Grado di inquinamento
Normale. Le batterie vanno smaltite secondo le
normative vigenti
Tipo di comunicazione
Infrarosso

7.6 Dimensioni

Vedi anche Figg. 3.10, 3.13 e 3.14.
8-38 Vdc.
Maximum power input: 900 mW
Cable cross-section: 28-16 AWG
The board is not optically-isolated. Refer to the user manual of the control it is installed on
IP00
-20T80°C, humidity 80% RH non-condensing
0T60°C, humidity <90% RH non-condensing
Normal
D
all the materials have PT≥250
A
long

7.5 Remote control

Assembly and installation instructions
If using this with a master fan coil, make sure that the resistor has been inserted
between terminals GN and V+ (on the fan coil) and that the receiver board
HYIR****** has been connected.
Warnings
Disconnect the power supply before performing any installation and maintenance
operations on the fan coil.
Adopt precautions against electrostatic discharges when handling the fan coil
board.
Technical specifi cations
Power supply
Storage conditions
Operating conditions
Degree of pollution
Type of communication
Tab. 7.11

7.6 Dimensions

Also see Figs. 3.10, 3.13 and 3.14.
160
52,81
74,48
ingombro scheda
HYFC0*
HYVC0*
52,81
62,99
160
Fig. 7.2:
dimensioni e-drofan/e-drofan dimensions
54
Two "AAA" 1.5V batteries.
-20T80°C, 80% RH non-condensing
0T60°C, <90% RH non-condensing
Normal. The batteries should be disposed of accor-
ding to the standards in force
Infrared
32,71
44,19
e-drofan manual +030221265 - rel. 1.0 - 04.08.2005