Saugen
Disassembly

Removing the operating element

Steps that must be completed:
-
Remove the cover
Tools:
-
Torx T15 (length: 89 mm)
-
PH1 cross-head screwdriver
-
Sleeve 70 mm inner diameter
1
2
3
4
6
C-SC_CSSM
1.
2.
3.
4.
5.
5
6.
7.
8.
Version 1.0
All rights reserved by FEIN, especially in case of property rights applications.
FEIN retains all rights of disposal, such as copying and circulation.
Remove the cables (1).
Remove the plug (2).
Unscrew the two screws (3).
Remove the socket.
Unscrew the two screws (4).
Remove the holder (5).
Remove the switch (6).
Press out the rotary knob.
N
!
OTE
Damage to the operating element.
The operating element can be damaged by excessive force.
Press out the rotary knob carefully.