Lennox SHGL-18VN-R Installation Instructions And Homeowner's Manual
Lennox SHGL-18VN-R Installation Instructions And Homeowner's Manual

Lennox SHGL-18VN-R Installation Instructions And Homeowner's Manual

18" & 24" dual-listed gas log sets

Advertisement

RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicinity
of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone.
Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
OTL REPORT NO. 116-L-11-5
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
INSTALLATION INSTRUCTIONS
AND HOMEOWNER'S MANUAL
SERENE HEAT SERIES
18" & 24" Dual-Listed Gas Log Sets
P/N 850,021M REV. B 03/2007
MODELS
SHGL-18VN-R
SHGL-18VP-R
SHGL-18MN-R
SHGL-18MP-R
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, AL-
TERATION, SERVICE OR MAINTENANCE CAN CAUSE IN-
JURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL.
FOR ASSISTANCE OR ADDITIONAL INFORMATION CON-
SULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE
GAS SUPPLIER.
WARNING: DO NOT BUILD A WOOD FIRE. DO NOT BURN
WOOD OR OTHER MATERIAL IN THESE APPLIANCES.
CAREFULLY REVIEW THE INSTRUCTIONS SUPPLIED WITH
THE DECORATIVE TYPE UNVENTED ROOM HEATER FOR
THE MINIMUM FIREPLACE SIZE REQUIREMENT.
DO NOT INSTALL THE APPLIANCE IN THE FIREPLACE, UN-
LESS THE FIREPLACE MEETS THE MINIMUM DIMENSIONS
REQUIRED FOR THE INSTALLATIONS (SEE PAGE 2).
This is an unvented gas log appliance. It uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventila-
tion air must be provided. Refer to Combustion
and Ventilation Air Section, Page 3.
Due to high temperatures, the appliance should be located out
of traffic and away from furniture or draperies (see page 4).
Do not place clothing or other materials on or near this
appliance.
IMPORTANT: READ AND UNDERSTAND THESE INSTRUCTIONS
COMPLETELY BEFORE INSTALLING YOUR UNVENTED ROOM
HEATERS.
SHGL-24VN-R
SHGL-24VP-R
SHGL-24MN-R
SHGL-24MP-R
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SHGL-18VN-R and is the answer not in the manual?

Questions and answers

Summary of Contents for Lennox SHGL-18VN-R

  • Page 1 INSTALLATION INSTRUCTIONS AND HOMEOWNER'S MANUAL SERENE HEAT SERIES 18" & 24" Dual-Listed Gas Log Sets P/N 850,021M REV. B 03/2007 MODELS SHGL-18VN-R SHGL-24VN-R SHGL-18VP-R SHGL-24VP-R SHGL-18MN-R SHGL-24MN-R SHGL-18MP-R SHGL-24MP-R RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: IMPROPER INSTALLATION, ADJUSTMENT, AL- TERATION, SERVICE OR MAINTENANCE CAN CAUSE IN- JURY OR PROPERTY DAMAGE.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS These appliances are equipped with a specially OWNER: PLEASE RETAIN THESE INSTRUC- designed pilot utilizing an oxygen depletion TION FOR FUTURE REFERENCE sensor (ODS) which responds to the amount General Information ......page IMPORTANT: READ THESE INSTALLATION of oxygen available in the room and shuts the Inventory .........
  • Page 3: Codes

    Rooms communicating directly with the space • Do not install the appliance in a bedroom or Serene Heat Gas Log appliances are certified by in which the appliances are installed, through bathroom. OMNI-Test Laboratories to ANSI Z21.11.2 un- vented room heaters standard. These gas log openings not furnished with doors, are con- •...
  • Page 4: Preinstallation

    4. Compare the maximum BTU/Hr the space CAUTION: APPLIANCES CREATE WARM AIR Follow these instructions carefully to ensure can support with the actual amount of BTU/ CURRENTS. THESE CURRENTS MOVE HEAT safe installation. Failure to follow these require- ments may create a fire hazard. Hr used.
  • Page 5 Example: The bottom of the mantel may project Noncombustible Material Requirements with No Mantel Installed from the wall a maximum of 2 ¹ ₂ " at a minimum of 8" above the opening. The top shelf of the (A) Noncombustible Material Measurement Requirements for Safe Installation mantel may project a maximum of 6"...
  • Page 6: Installation

    Step 2. Connecting Gas Line – A qualified gas B. Brush all joints and connections with the INSTALLATION appliance installer must connect the dual-listed gas leak test solution to check for leaks. If gas appliance to the gas supply. bubbles are formed, or gas odor is detected, WARNING: DO NOT ALLOW FANS TO turn the gas control knob to the “OFF”...
  • Page 7: Flame Appearance

    The pressure regulator on manual models is Grate Base preset and locked to avoid tampering. If the pressure is not as specified in the Technical Details Chart on page 10, replace the regulator with P/N 110353 for natural gas and P/N 120341 for propane (L.P.G.) heaters.
  • Page 8: Operation

    Propane Pilot Shown Figure 11 An incorrect pilot flame pattern is shown in Figure 12 . This pilot flame will cause the thermocouple to cool. When the thermocouple cools, the log set will shut off. If pilot flame pattern is incorrect, or if log set shuts off, contact your service technician.
  • Page 9 The Model RCL-T (Deluxe) Remote Control distributor contact: System has all of the features of the standard system along with an added easy to read LCD LENNOX HEARTH PRODUCTS screen which presents access to many en- 1110 West Taft Avenue hancements, including; battery power level...
  • Page 10: Millivolt Wiring Diagram

    PILOT (O.D.S.) ASSEMBY MILLIVOLT VALVE WHITE IGNITION WIRE WHITE OPTIONAL REMOTE CONTROL (MILLIVOLT) BLACK ON/OFF SWITCH AND PILOT IGNITOR MILLIVOLT WIRING DIAGRAM VENTED/UNVENTED GAS LOG APPLIANCE TECHNICAL CHART FOR MILLIVOLT LOG SET BTU/HR Regulator Gas Inlet Valve Model No. Input Gas Type Ignition Pres.
  • Page 11: Manual Wiring Diagram

    PILOT ASSY MANUAL VALVE IGNITION WIRE CONTROL KNOB AND PILOT IGNITOR MANUAL WIRING DIAGRAM VENTED/UNVENTED GAS LOG APPLIANCE TECHNICAL CHART FOR MANUAL LOG SET BTU/HR Regulator Gas Inlet Valve Model No. Input Gas Type Ignition Pres. Setting Pressure* Operation Orifice Size SHGL - 18MN-R 36,000 Natural...
  • Page 12: Operating Instructions - Manual

    OPERATING INSTRUCTIONS — MANUAL CONTROL MODELS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This heater has a pilot which must be lit by hand. When •...
  • Page 13 Pilot Gas Control Knob Location Pilot Location Figure 14 Figure 16 Turn Control Knob to “OFF” Position (Manual) Turn Control Knob to “IGN” Position (Manual) Figure 15 Figure 17 NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
  • Page 14: Operating Instructions - Millivolt

    LIGHTING INSTRUCTIONS – MILLIVOLT FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted with a piezo •...
  • Page 15: Troubleshooting Guide

    VENTED/UNVENTED TROUBLESHOOTING GUIDE OBSERVED PROBLEM POSSIBLE CAUSE REMEDY 1. When igniter button is A. Igniter electrode positioned wrong. Replace igniter. pressed, there is no spark at ODS/pilot. B. Igniter electrode broken. Replace igniter. C. Igniter electrode not connected to igniter cable. Reconnect igniter cable.
  • Page 16: Replacement Parts List - Millivolt

    REPLACEMENT PARTS LIST (MILLIVOLT) 18N/18P 24N/24P Description Part No. Part No. Valve, Millivolt (Natural) H1203 H1203 Valve, Millivolt (Propane, L.P.G.) 901917 901917 Base Log Assembly H1679 H1682 Front Log (Separate) H1680 H1683 Twig H1681 H1684 Burner H1196 H1196 Piezo Ignitor 10K86 10K86 Pilot, Millivolt (Natural)
  • Page 17 REPLACEMENT PARTS (MILLIVOLT) (Propane Pilot Shown) NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
  • Page 18: Replacement Parts List - Manual

    REPLACEMENT PARTS LIST (MANUAL) 18N/18P 24N/24P Description Part No. Part No. Valve, Manual (Natural) H1214 H1214 Valve, Manual (Propane, L.P.G.) H1319 H1319 Base Log Assembly H1679 H1682 Front Log (Separate) H1680 H1683 Twig H1681 H1684 Burner H1196 H1196 Piezo Ignitor 10K86 10K86 Pilot, Manual (Natural)
  • Page 19 REPLACEMENT PARTS (MANUAL) (Propane Pilot Shown) NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
  • Page 20 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2004 by Lennox Hearth Products 1110 West Taft Avenue P/N 850,021M REV.

Table of Contents