INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
Page 3
Thermal & Optical Bi-spectrum Network Camera User Manual PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
Page 4
Thermal & Optical Bi-spectrum Network Camera User Manual Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Indicates a hazardous situation which, if not avoided, will or could Danger result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, Caution could result in equipment damage, data loss, performance...
Page 5
Thermal & Optical Bi-spectrum Network Camera User Manual Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. Laws and Regulations ● Use of the product must be in strict compliance with the local electrical safety regulations. Transportation ●...
Page 6
Emergency ● If smoke, odor, or noise arises from the device, immediately turn off the power, unplug the power cable, and contact the service center. Manufacture Address No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China Hangzhou Hikvision Digital Technology Co.,Ltd...
Thermal & Optical Bi-spectrum Network Camera User Manual Contents Chapter 1 Overview........................1 1.1 Brief Description ........................1 1.2 Function ..........................1 Chapter 2 Device Activation and Accessing ................. 2 2.1 Activate the Device via SADP ....................2 2.2 Activate the Device via Browser ................... 2 2.3 Login ............................
Page 8
Thermal & Optical Bi-spectrum Network Camera User Manual 5.1.1 Normal Mode ......................17 5.1.2 Expert Mode ......................18 5.2 Set Video Tampering Alarm ....................19 5.3 Set Alarm Input ........................20 5.4 Set Exception Alarm ......................21 5.5 Detect Audio Exception ....................... 21 Chapter 6 Arming Schedule and Alarm Linkage .................
Page 9
Thermal & Optical Bi-spectrum Network Camera User Manual Chapter 8 Video and Audio ....................... 32 8.1 Video Settings ........................32 8.1.1 Stream Type ......................32 8.1.2 Video Type ........................ 32 8.1.3 Resolution ......................... 33 8.1.4 Bitrate Type and Max. Bitrate ................. 33 8.1.5 Video Quality ......................
Page 10
Thermal & Optical Bi-spectrum Network Camera User Manual 8.2.18 Digital Zoom ......................43 8.3 OSD ............................43 8.4 Set Privacy Mask ........................43 8.5 Overlay Picture ........................44 8.6 Set Manual DPC (Defective Pixel Correction) ..............44 8.7 Set Picture in Picture ......................45 Chapter 9 Video Recording and Picture Capture ................
Page 11
Thermal & Optical Bi-spectrum Network Camera User Manual 10.8 Enable Hik-Connect Service on Camera................57 10.8.1 Enable Hik-Connect Service via Web Browser ............57 10.8.2 Enable Hik-Connect Service via SADP Software ............ 58 10.8.3 Access Camera via Hik-Connect ................58 10.9 Set ISUP ..........................
Page 12
Thermal & Optical Bi-spectrum Network Camera User Manual 11.14 User and Account ......................68 11.14.1 Set User Account and Permission ................ 68 Chapter 12 Appendix ........................ 70 12.1 Common Material Emissivity Reference ................70 12.2 Device Command ....................... 70 12.3 Device Communication Matrix ..................71...
Thermal & Optical Bi-spectrum Network Camera User Manual Chapter 1 Overview 1.1 Brief Description Thermal & Optical Bi-spectrum network camera equipped with built-in GPU which supports intelligent behavior analysis algorithm, can realize high-precision VCA detection and real-time alarm. It is applied to perimeter defense and fire-prevention purposes in critical infrastructures such as community, villa, construction site, factory, 4S stores, and so on.
2.1 Activate the Device via SADP Search and activate the online devices via SADP software. Before You Start Access www.hikvision.com to get SADP software to install. Steps 1. Connect the device to network using the network cable. 2. Run SADP software to search the online devices.
Thermal & Optical Bi-spectrum Network Camera User Manual Note The default IP address of the device is 192.168.1.64. You can set the IP address of the PC from 192.168.1.2 to 192.168.1.253 (except 192.168.1.64). For example, you can set the IP address of the PC to 192.168.1.100.
Page 16
Thermal & Optical Bi-spectrum Network Camera User Manual with the wrong password reach the set times, the device is locked. Go to Configuration → System → Security → Security Service, and enable Enable Illegal Login Lock, and set the illegal login attempts.
Thermal & Optical Bi-spectrum Network Camera User Manual Chapter 3 Temperature Measurement When you enable this function, the device measures the actual temperature of the scene. It alarms when temperature exceeds the temperature threshold value. 3.1 Notice This part introduces the notices of configuring temperature measurement function. ●...
Thermal & Optical Bi-spectrum Network Camera User Manual Enable Color-Temperature Check to display Temperature-Color Ruler in live view. Display Temperature Info. on Stream Check to display temperature information on the stream. Display Temperature in Optical Channel Check to display thermal channel temperature information in the optical channel. Display Max./Min./Average Temperature Check to display maximum/minimum/average temperature information on liveview when the temperature measurement rule is line or area.
Thermal & Optical Bi-spectrum Network Camera User Manual Emissivity Set the emissivity of your target. The emissivity of each object is different. Distance The distance between the target and the device. Pre-Alarm Threshold When the temperature of target exceeds the pre-alarm threshold, and this status keeps more than Filtering Time, it triggers pre-alarm.
Thermal & Optical Bi-spectrum Network Camera User Manual Note Go to Image → VCA Rules Display to adjust the fonts size and the temperature colour of normal, alarm and pre-alarm. 3.2.4 Set Thermography Rule Steps 1. Customize the rule name. 2.
Thermal & Optical Bi-spectrum Network Camera User Manual alarm. E.g., set tolerance temperature as 3°C, set alarm temperature as 55°C, and set pre-alarm temperature as 50°C. The device sends pre-alarm when its temperature reaches 50°C and it alarms when its temperature reaches 55°C and only when the device temperature is lower than 52°C will the alarm be cancelled.
Thermal & Optical Bi-spectrum Network Camera User Manual 3.2.7 Area Thermography Configure the temperature measurement rule and monitor the maximum temperature of the area. Steps 1. Click and drag the mouse in the liveview to draw the area and right click to finish drawing. 2.
Page 23
Thermal & Optical Bi-spectrum Network Camera User Manual 3. Click Draw Area, then click the mouse on the black body in live view and save it. 4. Set the black body parameters. Emissivity: Set the emissivity of black body. Note Refer to the emissivity table for reference in the manual or online.
Thermal & Optical Bi-spectrum Network Camera User Manual Chapter 4 Body Thermography Body Thermography function can detect temperature of human face or body in the scene, and output alarm if the temperature is higher than the setting value. 4.1 Set Body Thermography Parameters Configure the parameters of body temperature measurement.
Thermal & Optical Bi-spectrum Network Camera User Manual Note Refer to the emissivity table for reference in the manual or online. Version View the version of current algorithm. 2. Click Save. 4.2 Set Body Thermography 4.2.1 Measure Body Temperature in Thermal Channel Steps: 1.
Thermal & Optical Bi-spectrum Network Camera User Manual 8. Set the arming schedule and linkage methods. For the information about arming schedule settings, see Set Arming Schedule. For the information about linkage methods, see Linkage Method Settings. 4.2.1 Measure Face Temperature in Optical Channel Steps: 1.
Page 27
Thermal & Optical Bi-spectrum Network Camera User Manual 9. Click Draw Area, and draw a face detection area in live view. You can move the rectangle or drag the corners of rectangle to adjust the position and size. Note You should draw the detection area within the red rectangle. 10.
Page 28
Thermal & Optical Bi-spectrum Network Camera User Manual Note You are allowed to draw up to 4 areas on the same image, and each area can be set with 3-10 points 3. Click Save. 4.3.3 Advanced Configuration Face Capture Version: It lists the version of the algorithms library. ...
Thermal & Optical Bi-spectrum Network Camera User Manual Chapter 5 Event and Alarm This part introduces the configuration of events. The device takes certain response to triggered alarm. 5.1 Set Motion Detection It helps to detect the moving objects in the detection region and trigger the linkage actions. Steps 1.
Thermal & Optical Bi-spectrum Network Camera User Manual Figure 6-1 Set Rules Stop Drawing Stop drawing one area. Clear All Clear all the areas. 4. Optional: You can set the parameters of multiple areas by repeating the above steps. 5.1.2 Expert Mode You can configure the motion detection parameters of day/night switch according to the actual needs.
Thermal & Optical Bi-spectrum Network Camera User Manual Figure 6-2 Set Rules Stop Drawing Finish drawing one area. Clear All Delete all the areas. 4. Optional: Repeat the above steps to set multiple areas. 5.2 Set Video Tampering Alarm When the configured area is covered and cannot be monitored normally, the alarm is triggered and the device takes certain alarm response actions.
Thermal & Optical Bi-spectrum Network Camera User Manual Figure 6-3 Set Video Tampering Area 6. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for setting linkage method. 7. Click Save. 5.3 Set Alarm Input Alarm signal from the external device triggers the corresponding actions of the current device.
Thermal & Optical Bi-spectrum Network Camera User Manual 5.4 Set Exception Alarm Exception such as network disconnection can trigger the device to take corresponding action. Steps 1. Go to Configuration → Event → Basic Event → Exception. 2. Select Exception Type. HDD Full The HDD storage is full.
Page 34
Thermal & Optical Bi-spectrum Network Camera User Manual environment. Sudden Decrease of Sound Intensity Detection Detect sudden decrease of sound intensity. Sensitivity is configurable. 3. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for setting linkage methods.
Thermal & Optical Bi-spectrum Network Camera User Manual Chapter 6 Arming Schedule and Alarm Linkage Arming schedule is a customized time period in which the device performs certain tasks. Alarm linkage is the response to the detected certain incident or target during the scheduled time. 6.1 Set Arming Schedule Set the valid time of the device tasks.
Thermal & Optical Bi-spectrum Network Camera User Manual Manual Alarm You can trigger an alarm output manually. Steps 1. Set the manual alarm parameters. Alarm Output No. Select the alarm output No. according to the alarm interface connected to the external alarm device.
Thermal & Optical Bi-spectrum Network Camera User Manual Refer to Set Memory Card for memory card storage configuration. 6.2.3 Send Email Check Send Email, and the device sends an email to the designated addresses with alarm information when an alarm event is detected. For email settings, refer to Set Email.
Thermal & Optical Bi-spectrum Network Camera User Manual 6.2.4 Notify Surveillance Center Check Notify Surveillance Center, the alarm information is uploaded to the surveillance center when an alarm event is detected. 6.2.5 Trigger Recording Check Trigger Recording, and the device records the video about the detected alarm event. For device with more than one camera channels, you can set one or more channels to take recordings if needed.
Page 39
Thermal & Optical Bi-spectrum Network Camera User Manual Note Only certain camera models support the function.
Thermal & Optical Bi-spectrum Network Camera User Manual Chapter 7 Live View It introduces the live view parameters, function icons and transmission parameters settings. 7.1 Live View Parameters Note For multichannel devices, select the desired channel first before live view settings. 7.1.1 Window Division ●...
Thermal & Optical Bi-spectrum Network Camera User Manual live view among multiple channels. Click to switch live view among multiple channels. 7.1.6 Full Screen This function is used to view the image in full screen mode. Click to start full screen mode and press ESC button to exit. 7.1.7 Light Click to turn on or turn off the illuminator.
Thermal & Optical Bi-spectrum Network Camera User Manual Note The function is only supported by certain models. 7.1.12 Lens Parameters Adjustment It is used to adjust the lens focus, zoom and iris. Zoom ● Click , and the lens zooms in. ●...
Page 43
Thermal & Optical Bi-spectrum Network Camera User Manual multicast address for them before selection. Note For detailed information about multicast, refer to Multicast. HTTP HTTP is suitable for the situation that the third-party needs to get the stream from the device.
Thermal & Optical Bi-spectrum Network Camera User Manual Chapter 8 Video and Audio This part introduces the configuration of video and audio related parameters. 8.1 Video Settings This part introduces the settings of video parameters, such as, stream type, video encoding, and resolution.
Thermal & Optical Bi-spectrum Network Camera User Manual 8.1.3 Resolution Select video resolution according to actual needs. Higher resolution requires higher bandwidth and storage. 8.1.4 Bitrate Type and Max. Bitrate Constant Bitrate It means that the stream is compressed and transmitted at a comparatively fixed bitrate. The compression speed is fast, but mosaic may occur on the image.
Page 46
Thermal & Optical Bi-spectrum Network Camera User Manual H.264 H.264, also known as MPEG-4 Part 10, Advanced Video Coding, is a compression standard. Without compressing image quality, it increases compression ratio and reduces the size of video file than MJPEG or MPEG-4 Part 2. H.265 H.265, also known as High Efficiency Video Coding (HEVC) and MPEG-H Part 2, is a compression standard.
Thermal & Optical Bi-spectrum Network Camera User Manual 8.1.8 Smoothing It refers to the smoothness of the stream. The higher value of the smoothing is, the better fluency of the stream will be, though, the video quality may not be so satisfactory. The lower value of the smoothing is, the higher quality of the stream will be, though it may appear not fluent.
Thermal & Optical Bi-spectrum Network Camera User Manual some extent. 8.1.11 Two-way Audio It is used to realize the two-way audio function between the monitoring center and the target in the monitoring screen. Before You Start ● Make sure the audio input device (pick-up or microphone) and audio output device (speaker) connected to the device is working properly.
Thermal & Optical Bi-spectrum Network Camera User Manual Note The higher the ROI level is, the clearer the image of the detected region is. 8. Optional: Select other region No. and repeat the above steps if you need to draw multiple fixed regions.
Thermal & Optical Bi-spectrum Network Camera User Manual ● Self-Adaptive: Choose AGC mode automatically according to current scene. 8.2.3 Exposure Settings Exposure is controlled by the combination of iris, shutter, and photo sensibility. You can adjust image effect by setting exposure parameters. In manual mode, you need to set Exposure Time, Gain and Slow Shutter.
Thermal & Optical Bi-spectrum Network Camera User Manual according to the image brightness. Brightness Limit Adjust the upper limit of IR light power. 8.2.6 BLC If you focus on an object against strong backlight, the object will be too dark to be seen clearly. BLC (backlight compensation) compensates light to the object in the front to make it clear.
Thermal & Optical Bi-spectrum Network Camera User Manual 8.2.10 Set Palette You can select the palette mode to display the thermal grayscale image to colored image. Steps 1. Go to Configuration → Image → Display Settings. 2. Select the thermal channel. 3.
Page 53
Thermal & Optical Bi-spectrum Network Camera User Manual Figure 9-1 Set the Temperature and Color of Target Above (be colored) When the target of high temperature needs to be colored, you can set the high temperature color. Target above the setting temperature will be displayed in setting color. Between (be colored) When the target of an interval temperature needs to be colored, you can set the interval temperature color.
Thermal & Optical Bi-spectrum Network Camera User Manual 5. Click Save. 8.2.13 DDE Digital Detail Enhancement is used to adjust the details of the image. OFF and Normal modes are selectable. Disable this function. Normal Set the DDE level to control the details of the image. The higher the level is, the more details shows, but the higher the noise is.
Thermal & Optical Bi-spectrum Network Camera User Manual and PAL. In NTSC, 30 frames are transmitted each second. Each frame is made up of 525 individual scan lines. In PAL, 25 frames are transmitted each second. Each frame is made up of 625 individual scan lines.
Thermal & Optical Bi-spectrum Network Camera User Manual 6. Click Save. Note Up to 4 areas are supported for setting. 8.5 Overlay Picture Overlay a customized picture on live view. Before You Start The picture to overlay has to be in BMP format with 24-bit, and the maximum picture size is 128 × 128 pixel.
Thermal & Optical Bi-spectrum Network Camera User Manual 8.7 Set Picture in Picture You can overlay the images of two channels and view the image of two channels at the same time. Steps 1. Select a channel number. 2. Select the picture in picture mode. Normal Mode Disable picture in picture mode.
Thermal & Optical Bi-spectrum Network Camera User Manual Chapter 9 Video Recording and Picture Capture This part introduces the operations of capturing video clips and snapshots, playback, and downloading captured files. 9.1 Storage Settings This part introduces the configuration of several common storage paths. 9.1.1 Set Memory Card If you choose to store the files to memory card, make sure you insert and format the memory card in advance.
Thermal & Optical Bi-spectrum Network Camera User Manual The saving path of network disk files. User Name and Password The user name and password of the net HDD. 3. Click Test to check whether the network disk is available. 4. Click Save. 9.1.3 Set FTP You can configure the FTP server to save images which are captured by events or a timed snapshot task.
Thermal & Optical Bi-spectrum Network Camera User Manual 3. Set basic parameters. Protocol Version The protocol version of the cloud storage server. Server IP The IP address of the cloud storage server. It supports IPv4 address. Serve Port The port of the cloud storage server. 6001 is the default port and you are not recommended to edit it.
Thermal & Optical Bi-spectrum Network Camera User Manual movement is recorded. Alarm When alarm input is enabled and trigger recording is selected as linkage method, the video is recorded after receiving alarm signal from external alarm input device. Motion | Alarm Video is recorded when motion is detected or alarm signal is received from the external alarm input device.
Thermal & Optical Bi-spectrum Network Camera User Manual 9.2.3 Playback and Download Video You can search, playback and download the videos stored in the local storage or network storage. Steps 1. Click Playback. 2. Select channel No. 3. Set search condition and click Search. The matched video files showed on the timing bar.
Thermal & Optical Bi-spectrum Network Camera User Manual Event-Triggered Capture a picture when an event is triggered. 3. Set the Format, Resolution, Quality, Interval, and Capture Number. 4. Refer to Set Arming Schedule for configuring schedule time. 5. Click Save. 9.3.2 Capture Manually Steps 1.
Thermal & Optical Bi-spectrum Network Camera User Manual Chapter 10 Network Settings 10.1 TCP/IP TCP/IP settings must be properly configured before you operate the device over network. IPv4 and IPv6 are both supported. Both versions can be configured simultaneously without conflicting to each other.
Thermal & Optical Bi-spectrum Network Camera User Manual Manual Input IPv6 Address, IPv6 Subnet, IPv6 Default Gateway. Consult the network administrator for required information. It stands for maximum transmission unit. It is the size of the largest protocol data unit that can be communicated in a single network layer transaction.
Thermal & Optical Bi-spectrum Network Camera User Manual 10.3 Port Mapping By setting port mapping, you can access devices through the specified port. Before You Start When the ports in the device are the same as those of other devices in the network, refer to Port to modify the device ports.
Thermal & Optical Bi-spectrum Network Camera User Manual 10.4 Multicast Multicast is group communication where data transmission is addressed to a group of destination devices simultaneously. After setting multicast, you can send the source data efficiently to multiple receivers. Go to Configuration → Network → Basic Settings → Multicast for the multicast settings. IP Address It stands for the address of multicast host.
Thermal & Optical Bi-spectrum Network Camera User Manual can be mapped to a domain name resolution server to realize the network access via domain name. Before You Start Registration on the DDNS server is required before configuring the DDNS settings of the device. Steps 1.
Thermal & Optical Bi-spectrum Network Camera User Manual Confirm Input your dial-up password again. 4. Click Save. 5. Access the device. By Browsers Enter the WAN dynamic IP address in the browser address bar to access the device. By Client Software Add the WAN dynamic IP address to the client software.
Thermal & Optical Bi-spectrum Network Camera User Manual 10.8.2 Enable Service via SADP Software Hik-Connect This part introduce how to enable Hik-Connect service via SADP software of an activated camera. Steps 1. Run SADP software. 2. Select a camera and enter Modify Network Parameters page. 3.
Thermal & Optical Bi-spectrum Network Camera User Manual 4. Select a protocol version and input related parameters. 5. Click Save. Register status turns to Online when the function is correctly set. 10.10 Set ONVIF If you need to access to the device through ONVIF protocol, you can configure the ONVIF user to enhance the network security.
Thermal & Optical Bi-spectrum Network Camera User Manual Chapter 11 System and Security It introduces system maintenance, system settings and security management, and explains how to configure relevant parameters. 11.1 View Device Information You can view device information, such as Device No., Model, Serial No. and Firmware Version. Enter Configuration →...
Thermal & Optical Bi-spectrum Network Camera User Manual 11.4 Export Diagnose Information Diagnose information includes running log, system information, hardware information. Go to Configuration → System → Maintenance → Upgrade & Maintenance, and click Diagnose Information to export diagnose information of the device. 11.5 Reboot You can reboot the device via browser.
Thermal & Optical Bi-spectrum Network Camera User Manual 2. Choose one method to upgrade. Firmware Locate the exact path of the upgrade file. Firmware Directory Locate the directory which the upgrade file belongs to. 3. Click Browse to select the upgrade file. 4.
Thermal & Optical Bi-spectrum Network Camera User Manual Note Server Address is NTP server IP address. 5. Click Test to test server connection. 6. Click Save. 11.9.3 Set DST If the region where the device is located adopts Daylight Saving Time (DST), you can set this function.
Thermal & Optical Bi-spectrum Network Camera User Manual Note You should keep the parameters of the device and the computer or terminal all the same. 3. Click Save. 11.12 Set Same Unit Set the same temperature unit and distance unit. When you enable this function, the unit cannot be configured separately in other setting pages Steps 1.
Thermal & Optical Bi-spectrum Network Camera User Manual WEB Digest Algorithm MD5, SHA256 and MD5/SHA256 encrypted algorithm in WEB authentication. If you enable the digest algorithm except for MD5, the third-party platform might not be able to log in to the device or enable live view because of compatibility.
Thermal & Optical Bi-spectrum Network Camera User Manual Forbidden IP addresses in the list cannot access the device. Allowed Only IP addresses in the list can access the device. 4. Edit the IP address filter list. Add a new IP address to the list. Modify Modify the selected IP address in the list.
Thermal & Optical Bi-spectrum Network Camera User Manual Create and Install Self-signed Certificate Steps 1. Check Create Self-signed Certificate. 2. Click Create. 3. Follow the prompt to enter Country, Hostname/IP, Validity and other parameters. 4. Click OK. Result The device will install the self-signed certificate by default. Install Authorized Certificate If the demand for external access security is high, you can create and install authorized certificate via HTTPS protocol to ensure the data transmission security.
Thermal & Optical Bi-spectrum Network Camera User Manual Note Network can identify the priority of data transmission. The bigger the DSCP value is, the higher the priority is. You need to set the same value in router while configuration. 3. Click Save. 11.13.7 Set IEEE 802.1X You can authenticate user permission of the connected device by setting IEEE 802.1X.
Page 81
Thermal & Optical Bi-spectrum Network Camera User Manual creating accounts. Modify Select a user and click Modify to change the password and permission. Delete Select a user and click Delete. Note The administrator can add up to 31 user accounts. 3.
0.98 Hard Paperboard 0.90 White Paper 0.90 Water 0.96 12.2 Device Command Scan the following QR code to get device common serial port commands. Note that the command list contains the commonly used serial port commands for Hikvision thermal cameras.
Thermal & Optical Bi-spectrum Network Camera User Manual 12.3 Device Communication Matrix Scan the following QR code to get device communication matrix. Note that the matrix contains all communication ports of Hikvision thermal cameras.