16
Appendix B – Communications
READ Example:
If the sending unit wishes to read the number of points that the
CAT1 has in the K factor table, the sending unit shall send
The CAT1 echoes the sent message, and responds with
WRITE Example:
If the sending unit wishes to change the number of points to 20 in
the K factor table, the sending unit shall send
The CAT1 echoes the sent message and responds with
The CAT1 checks the ranges for data and rejects writes that are not
within the allowed range. If the sending unit sends data that is not
within the allowed range, the CAT1 echoes the sent message and
responds with the value that is currently stored in the CAT1.
Example:
If the sending unit wishes to change the max sample time to 2000
from the previous setting of 10, the sending unit shall send
The CAT1 echoes the sent message, and responds with
HP-310
"NP<CR>"
"NUM PTS
"NP=20<CR>"
"NUM PTS
"NB=2000<CR>"
"MAX M TIME=
=
2<CR>"
=
20<CR>".
10<CR>".