Table of Contents About this Installation Guide ..2 AC- and DC-Connection ....17 Safety Symbols....... 3 Starting the Inverter ...... 21 General Safety Requirements ..4 Configuration ........ 22 Intended Use ........5 Opening the Inverter ..... 24 Inverter Function......8 Digital Input / Labels and Markings on Digital Output ........
About this Installation Guide This installation guide describes the Terms: PSI-1100TL-ECO safe installation of the inverters listed Installer Qualified technician Max. DC-Power 1100 W on the left. in charge of the Max. AC-Power 1000 W Target group: installation Qualified technicians...
Safety Symbols Life threatening voltages are Countermeasures that must processed inside the inverter. be taken in order to avoid the Hazardous situations that can lead to hazardous situation are indicated with death or serious injuries are indicated an arrow: with the “WARNING” symbol (1) on Î...
General Safety Requirements 1. WARNING! Danger of electric WARNING! Danger of shock! electric shock and fire! Î Read Installation Guide Î Never modify the inverter unless carefully. Follow all explicitly instructed to do so by the instructions. manufacturer. 2. Contact your supplier when you Keep this installation guide near the have questions.
Intended Use The inverter (1) converts DC-power CAUTION! Risk of damaging the inverter! from the PV-generator (2) to AC- power. The AC-power is fed into the Î Do not connect other DC-power grid (3). In case of a grid failure: The sources (6) such as wind power inverter automatically disconnects systems, hydroelectric generators,...
Page 8
Electrical Safety 1. WARNING! Risk of electric 2. The inverter is not shock! The PV-panels emit a equipped with an internal dangerous DC-voltage when isolation transformer exposed to sunlight. 3. Local regulations and standards can require that an isolation transformer is additionally installed.
Page 9
DC-Disconnect / RCD 1. Local regulations and standards 2. The inverter is equipped can require that current-breakers with an integrated RCMU are installed on the DC-side. Type B (tested according to EN Contact your utility operator if you 62109-2 / IEC 60755). If local have questions.
Inverter Function 1. DC-side surge voltage protection 8. Digital output port 2. DC-side insulation monitoring 9. Digital input port 3. DC-side disconnection switch 10. Communication extension port (optional) 11. Residual Current Device (RCD) 4. Display, status LEDs, pushbutton 5. AC-side disconnection relay 6.
Labels and Markings on the Inverter Symbols on Type Label: Markings and Symbols on General Symbols bottom of Inverter: 1. Ensure proper disposal 7. AC-plug 2. CE-mark 8. Service port: Not used Safety Symbols 9. Digital I/O 3. Read documentation! 10.
Connections on the Inverter 1. Additional PE-connection 2. DC-plugs 3. AC-plug 4. Cable gland for digital input and digital output 5. Optional communication port 6. Service port: Not used Collegamenti con l’inverter 1. Collegamento aggiuntivo alla protezione di terra 2. Connettore CC 3.
User Interface 1. Green LED: 3. Pushbutton: - On = Normal operation, Pressing < 1 s: Next - Flashing = Waiting, checking or Pressing > 2 s: Enter starting up, 4. LCD - Off = Possible failure 5. Configuration in the menu is 2.
Unpacking Proceed as follows: • Check the packaging for damages. • Unpack the inverter and check if all items of the packing list are included. • Check all items for visible damages. Contact your supplier when items are missing or the inverter is damaged. Do not install a damaged inverter.
Page 15
Required Tools The following tools are required for 7. Screwdriver the installation of the inverter: 8. Hammer 1. Crimping tool for DC-plugs 9. Level (e.g. type PV-CZM) 10. Hex key (4mm) 2. Cable stripping tool for DC-cables (e.g. PV-AZM) 3. Drill 4.
Mounting the Inverter Requirements for the installation location are specified on the following pages. Proceed as follows: 1. Screw wall mounting bracket to wall. 2. Hang inverter on wall mounting bracket. 3. Check correct position. 4. Optional: Secure the inverter with a padlock.
Page 17
min. 50 cm min. 50 cm min. 50 cm min. 50 cm 14.7 cm min. 33.4 cm 50 cm 15.7 cm 14.7 cm min. 33.4 cm 50 cm 15.7 cm 20.0 cm 20.0 cm 10.5 cm 10.5 cm 19.0 cm 19.0 cm 13 kg 13.0 cm...
Page 18
e r t i e d I n v r . c m i l d - t G r i l a r r . c I n v e r t d - t i e d G r i m i l l a r 0 / 4...
AC-Connection - Requirements 1. Use 16 A circuit breaker. 4. The maximum outer 2. WARNING! Risk of fire! diameter of the AC-cable is Î Do not connect any consumers 14 mm. to the AC-line. The wire size is 2.5 - 4 mm 3.
Page 20
Assembly of the AC-Plug WARNING! Risk of electric shock! 5. Remove swivel nut and Î Deactivate AC-voltage when shove components over connecting the AC-connection cable. plug. 6. Attach wires to AC-plug. 0 V ? Proceed as follows: 7. Shove plug housing into plug 1.
Page 21
DC-Connection - Requirements 1. CAUTION! Risk of damaging the 4. The DC-ports can be PSI-1100TL inverter! connected: Install diodes PSI-1600TL < 500 V Î Ensure that the voltage and in order to avoid reverse currents. PSI-2100TL current is below the specified 5.
Page 22
Assembly of the DC-Plugs WARNING! Risk of electric shock! 5. Insert plug contact in plug. 6 - 7.5 mm Î Cover PV-modules when working Pull on contact in order to on the connection cables. check that the contact is locked in Proceed as follows: the plug.
Starting the Inverter Proceed as follows: In case you are starting the 1. Connect AC-plug. inverter for the first time: 2. Connect DC-plugs. The inverter needs to be 3. If present: Turn DC-switch on. commissioned. Commissioning is 4. Turn AC-fuse on. described in English on page 22.
Configuration of the Inverter 1. Press pushbutton less than 1 sec. 5. The inverter can be set to UPV = 272.4V Pac =1535.7W several times until you reach the factory default by selecting “Setting” menu. “FactorySet” 2. Press pushbutton long in order to IPV = 5.2A enter the “Setting”...
Configurazione dell’inverter 1. Premere il tasto per meno di 5. L’inverter può essere UPV = 272.4V Pac =1535.7W 1 sec. più volte fino a quando ripristinato alle compare il menu “Setting”. impostazioni di fabbrica 2. Premere il tasto più a lungo per selezionando “FactorySet”.
Opening the Inverter Do not open the inverter. There are no user servicable parts inside the inverter. Apertura dell’inverter Non aprire l’inverter. Nell’alloggiamento non ci sono componenti rilevanti per l’utilizzatore.
Digital Input / Digital Output The inverter is equipped with the Schematic diagrams of following interfaces: examples for connecting the digital 1. 1 digital output port (relay) for ports are available on the following switching external loads pages. 2. 4 digital input ports for power derating by the utility operator Configuration of the input and output ports is done with PSI Browser.
Page 28
Digital Input Ports The inverter is equipped with 4 digital input ports (1). The digital input ports can be used for the connection of a ripple control receiver (2). RS232 RS232 I/O PORT I/O PORT Ingressi digitali L’inverter è dotato di 4 ingressi digitali (1).
Page 29
Digital Output The inverter is equipped with 1 digital output port (relay) (1). The usage is possible with future firmware versions. Uscita digitale L’inverter è dotato di 1 uscita digitale (relè) (1). Esse possono essere utilizzate con versioni di firmware successive. RS232 RS232 I/O PORT...
Commissioning Autotest function is available in the SETTINGS menu when IT- CEI 0-21 has been selected. 1. To start the AUTOTEST, you need to press and hold the button for 2s until > 2 s the function AUTOTEST is displayed. 2.
Messa in Funzione La funzione Autotest è disponibile nel menu IMPOSTAZIONI quando è stato selezionato IT-CEI 0-21. 1. Per avviare l’AUTOTEST, occorre tenere premuto il pulsante per 2 secondi > 2 s finché non viene visualizzata la funzione AUTOTEST. 2. Avvio automatico dell’autotest. 3.