Fujitsu PRIMERGY LTO3 User Manual page 70

Tape drv ultrium3 400gb
Table of Contents

Advertisement

Available languages

Available languages

2.2.3
How to use forcible ejection when the data
cartridge cannot be ejected
The data cartridge can be forcibly ejected by pressing the eject button for more than 10 seconds
(Forcible ejection). Only use "Forcible ejection" when the data cartridge cannot be ejected due to an
error. Do not use it in normal circumstances.
"Forcible ejection" is a function that prevents the leakage of customers' data. Performing "Forcible
ejection" may cause damage to the data cartridge or this product rendering them unable to be used.
Make sure that the data cartridge cannot be ejected using normal operations or software before
performing "Forcible Ejection".
Performing "Forcible ejection" may cause damage to the data cartridge. Data cannot
be guaranteed.
After forcibly ejecting a tape do not use the same tape again.
When a data cartridge cannot be ejected using normal procedures ( " Manually ejecting a data
cartridge"(pg.68)) use the following procedures.
1
Press the eject button for more than 10 seconds (Forcible
ejection).
The Ready LED blinks and the cartridge is forcibly ejected. It may take several minutes
(max. 15 minutes) to rewind the tape. Wait if the Ready LED is blinking.
2
If the data cartridge is still not ejected, press the emergency reset
button. (Use the tip of a paper clip or some other thin object to
press the button).
This product is reset.
Wait if the Ready LED is still blinking.
3
When the Ready LED turns on, press the eject button for 10
seconds to forcibly eject the data cartridge.
If the data cartridge cannot be ejected using these procedures, it is possible that this product may be
broken.
Contact an office listed in "Appendix B Contact Information" ( pg.88).