Bonding:
A lug used for bonding is attached to the bottom of the Excelpool
System enclosure (see diagram below). The Excelpool System
must be bonded with an 8 AWG copper wire (6 AWG Canada)
to the pool bonding system.
Electrolytic Cell and Flow Switch:
The electrolytic cell and flow switch cables are terminated with
connectors that plug into the Excelpool System for easy
attachment and removal. The door of the Excelpool System
must be open to access the cell cable connector. The flow
switch plugs into a connector (similar to a telephone jack)
located outside, on the bottom of the enclosure. Refer to the
diagram below for the location of these connections.
Input power for use with Goldline, Pentair and Polaris controls:
Wire the Excelpool System DIRECTLY TO 120/240VAC
POWER (not through timer or relay).
Optional Goldline, Pentair and Polaris controls:
The Goldline, Pentair and Polaris controls use a 4 wire
connection to communicate to the Excelpool System and can be
wire up to 500' apart. Any outdoor rated 4 conductor cable can
be used. Refer to each manufacturer's instructions and the wiring
diagrams below for proper wiring connection to the Excelpool
System.
23 |