To find the optimum "Desired Level %" setting, start at a fairly high
setting and work downward. It will take a few days of adjustments
to find the ideal setting for your pool. Once determined, it should
only take minor adjustments. The Excelpool System control will
not produce chlorine at temperatures below 50°F If your pool
water is colder than 50°F, you must chlorinate manually.
Maintaining the System
To maintain maximum performance, it is recommended that
you remove and visually inspect the cell every 3 months. The
Excelpool System will remind you to do this by flashing the
"Inspect Cell" LED after approximately 500 hours of operation.
After you inspect the cell (and clean, if necessary) press the
small "diagnostic" button next to the display for 3 seconds to
stop the flashing "Inspect Cell" LED and start the timer for the
next 500 hour inspection period.
The Excelpool System electrolytic cell has a self-cleaning
feature incorporated into the electronic control's logic. In most
cases this self-cleaning action will keep the cell working at
optimum efficiency. In areas where water is hard (high calcium
and/or mineral content) and in pools where the water chemistry
has gotten "out of balance", the cell may require periodic
cleaning. The "Inspect Cell" LED remains on after a thorough
cleaning, the cell may be worn and may require replacement.