Auerswald COMfortel WS-R2 Setup Manual page 27

Ip-dect repeater
Hide thumbs Also See for COMfortel WS-R2:
Table of Contents

Advertisement

Available languages

Available languages

Click the Repeater tab.
1.
1.
4.
Click Read from Repeater (optional).
2.
This displays the settings that are saved in the repeater.
Note: This step is only necessary if the repeater was pro-
grammed before.
Click Multi Cell Solution to configure the repeater for a multi
3.
cell system.
The user interface and button texts vary according to
which settings are active.
Make the following settings:
4.
Multi Cell Solution: Enter the ARI of the IP-DECT server.
You will find the ARI on the back of the IP-DECT server or
in the configuration manager under Status > Wireless
Server.
Number of channels to transfer (Busy Bit): Enter the
number of voice channels you want the repeater to man-
age (for COMfortel WS-R2, maximum 2 channels, for
COMfortel WS-R4, maximum 4 channels).
Base station to synchronize on: Enter the number of the
base station you want the repeater to synchronise with.
You will find this number in the IP-DECT server configura-
tion manager under Administration > Base station in
the RPN field.
Note: When using a COMfortel WS-400 IP, the RPN is always 0.
Repeater number: Enter a number for the repeater. You
can make the following entries: A number between 0 and
255.
COMfortel WS-R2/WS-R4 - Setup Guide V04 11/2015
Commissioning
2.
5.
3.
27