Regrind Control - MAGUIRE Weigh Scale Blender 4088 TSC Installation Operation & Maintenance

Touch screen controller, receiver control system
Table of Contents

Advertisement

Regrind Control

Regrind Control is a set of parameters that enhance control of regrind.
PRN 00000 - Percent of Regrind to be Treated as Natural
First digit: 0 = adds, 1 = subtracts ... additive to or from the regrind.
Second digit: Regrind component.
Third digit: 0 = all additives. Entering a number specifies that additive component only.
Last 2 digits: Percent of Regrind. 99 = 100.
Example: 01030 - 0=add, 1=Regrind in 1, 0=all additives, 30% of regrind as natural.
3rd digit should use 1-9, A, B, C for component numbers.
RAC 000000 - Regrind Auto Control (six-digit parameter)
First digit is the regrind component
Second and 3rd digits are the cycle count
Last 3 digits are the % to increase current setting by.
Example: 110100 - Regrind #1, 10 cycles increase setting by 100%. Current
setting 25%, increases to 50%.
RLC 00000 - Regrind Level Control – works with RHL
First digit is the regrind component (1-9 only)
Last digit the % to increase current setting when the sensor is covered and uncovered.
Example: 10005 - Regrind #1 increase 5% each cycle based on RHL setting.
RHL 00000 - High Low Level Control - Requires level sensors
First 3 digits is the high percentage when upper sensor is covered
Last 2 digits are the low percentage when both sensors are uncovered.
Example 07020. Regrind setting at 50. If both sensors are covered increase
setting to 70%. If both sensors are uncovered decrease setting to 20%.
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flexbus lite

Table of Contents