TROUBLESHOOTING - What To Do
1. If you are reading this section, you are having problems. To locate and correct the problem
we suggest that you take the following steps:
2. Start by reading the WIRING CONSIDERATIONS section. Even if the system worked well
for a time, dry weather or increased plant electrical noise can cause new problems.
3. Then follow the CHECKOUT procedure in the front of this manual. If anything does not
work right, read the diagnostics section that follows it.
4. Read the section on NORMAL OPERATING SEQUENCE to be sure you understand what
it is supposed to be doing. If you are still unsure as to how the software logic works, call
us.
5. Read the list of TYPICAL PROBLEMS that follows on the next page.
6. Read the section on VERIFYING LOAD CELL function to be sure that the load cells are
operating correctly.
7. For difficult problems we can provide the most help if we have a printout of the
PARAMETER table and a digital printout the Cycle History (Print Cycle History under Print
Center).
8. Try a Factory Reset. Turn power off.
Print the PARAMETER Table:
Press
Press
System Configuration
Press
Diagnostics
Press
System Print Options
Press
Print Parameters
Press
Alarms - Cause and Solution
82
Display will prompt for a password. (default: 22222)
Display will show the System Configuration categories.
Display will show System Diagnostics Options
Display will show System Print Options:
Print Totals, Print Alarm History, Print Cycle History,
Print Parameters, Print Alarm and Events, Print All.
System will print parameters to USB to a file labeled:
PRINTER.TXT located in a folder named "maguire".
To save and exit or press the red X to cancel
and exit.
Then press: