3.1.4.9 Cutting head installation
At ex-factory, to ensure safety and prevent the laser head from being polluted during transportation, the
cutting head (focus canister) of some types of machine are individually packaged and kept. During installation of
the equipment, they should be replaced back.
30
Figure 3-18
Removal of fixation block Diagram
Light inlet
Cutting head
Lockup for some types machine
Blower pipe joint
Air jet ring
Light route adjusting bolt
Figure 3-19
Cutting Head Structure Diagram
Y fixation block
X fixation block
Lens fastening screw
Focus canister
Focus lens
Lens fastening cushion
Lens fastening screw
Light outlet