Yueming CMA0604-B-A Product Operation Manual page 31

Table of Contents

Advertisement

Attention
Attention
3.1.4.4 Water cooling system installation
3.1.4.4.1
Water tank + water pump installation:
Fill up water tank with distilled water;
Securely connect water pump and water outlet connector, insert water hose, and place it into the water
tank;
Pass the water hose connecting to the water pump through the small hole in the water tank cover and
connect it to water inlet of the machine, and then connect another water hose to water outlet of the
machine and place it into the water tank to complete water circulation piping connection;
Connect a patch board with circuit breaker or overcurrent protection. The input voltage is 220-240V AC,
50/60Hz.
Connect through power supply. At this time, you will find that water is gradually filled up the laser tube,
smooth water flow in the water outlet indicates normal operation of the water pump.
26
machine, are required. Otherwise, sparkle and serious interference may possibly caused
and influencing on the operation of the equipment. Serious current leakage is dangerous
to human body.
During operation of the machine and after power-off, please do not touch the high
voltage line with hand. Otherwise, electric shock or even death may be caused.
Figure 3-13
Water and Gas Installation of the Machine
Water outlet
Water inlet
Inlet port