High Pressure Abrasive Blast Cabinet
Attach the two dust collectors #20 on both sides
of the cabinet assembly #1 with M6*12 bolts
(8PCS). Note: The longer electrical cord on left
side dust collector allowing cord to reach power
box.
15

Advertisement

loading
Need help?

Need help?

Do you have a question about the 42000 and is the answer not in the manual?

Questions and answers

Bryan A Bell
January 31, 2025

Hello ,having trouble with Allsource model 42000 cabinet blaster, **** presure remains low and doesnot build pressure is at 110 psi. Not sur which part needs replacement

1 comments:
Mr. Anderson
February 10, 2025

For low pressure issues in the Allsource model 42000 cabinet blaster, check and possibly replace the nozzle if it is clogged or worn out. Additionally, ensure there is sufficient media in the pressure tank.