1778-Drive Array Resuming Automatic Data Recovery Process; 1783-Slot X Drive Array Controller Failure - HP ProLiant Troubleshooting Manual

Hide thumbs Also See for ProLiant:
Table of Contents

Advertisement

x
Check the LEDs. If the ProLiant Storage System power LED is amber instead of green, this indicates a
redundant power supply failure.
x
If the message indicates to check SCSI cables, do the following:
Compare the cabling against the diagrams in the HP Smart Array Controller User Guide.
a.
If the routing is correct, replace cables on the specified port until the POST error message is
b.
eliminated.

1778-Drive Array Resuming Automatic Data Recovery Process

Audible Beeps: None
Possible Cause: A controller reset or power cycle occurred while Automatic Data Recovery was in
progress.
Action: No action is required.
1779-Slot X Drive Array - Replacement drive(s) detected OR previously failed
drive(s) now operational:...
...Port Y: SCSI ID Z:
Restore data from backup if replacement drive X has been installed.
Audible Beeps: None
Possible Cause: More drives failed (or were replaced) than the fault-tolerance level allows. Unable to
rebuild array. If drives have not been replaced, this message indicates an intermittent drive failure.
Action: Be sure the system is always powered up and down correctly:
x
When powering up the system, all external storage systems must be powered up before (or at the
same time as) the server.
x
When powering down the system, the server must be powered down before powering down any
external storage systems.

1783-Slot X Drive Array Controller Failure

Audible Beeps: None
Possible Cause: The controller failed.
Action:
Reseat the array accelerator module.
1.
Reseat the controller in the PCI slot.
2.
Update the controller to the latest firmware version
3.
If the problem persists, replace the controller.
4.
("Firmware
maintenance" on page 80).