HP ProLiant Troubleshooting Manual page 25

Hide thumbs Also See for ProLiant:
Table of Contents

Advertisement

Audible Beeps: None
Possible Cause: An application has overwritten memory reserved by the Smart Array controller.
Action: If this occurs when a particular application is loaded, check for an updated version of that
application.
1707 - Slot X Drive Array Controller - Bootstrap NVRAM checksum failed
The second line of the message includes one of the following lines of text:
(unrecoverable error)
or
(no suitable backup found)
Audible Beeps: None
Possible Cause: The Bootstrap NVRAM on the specified Smart Array controller is corrupt or invalid.
Action:
Update the controller with the latest firmware version.
1.
If the problem still exists, replace the controller.
2.
1708 - Slot X Drive Array Controller - Bootstrap NVRAM restored from backup.
System restart required
Audible Beeps: None
Possible Cause: The specified Smart Array controller Bootstrap NVRAM was restored in one of the
following ways:
x
It was detected as corrupt, and the backup copy was restored.
x
It was automatically updated because a newer version was available.
Action:
Reboot the server.
1.
If the problem still exists, update the controller to the latest firmware version.
2.
1711-Slot X Drive Array - RAID ADG logical drive(s) configured but Array
Accelerator size <= 32 MB
...This configuration is not recommended. Consider migrating logical drive(s) to RAID 5 or upgrading the Array
Accelerator module.
Audible Beeps: None
Possible Cause: This configuration is not recommended.
Action: Migrate logical drives to RAID 5 or upgrade to a larger array accelerator module.
1711-Slot X Drive Array - Stripe size too large for RAID 5/6 logical drive(s)
...This configuration is not recommended due to transfer buffer usage. Consider migrating to lower stripe size via
Array Configuration Utility.