12.3 Modes of Operation:
Single Phase Current and Voltage
Manual Configuration
In some applications, such as those where conductors are
armoured, the logger may fail to configure automatically. In
these instances, it may still be possible to get it to configure.
Phase Matching Diagram
This is a tool that may help to visualise the separation of coils
that are too close to each other.
To get to the diagram , press and hold the scroll key and
press the function key at the same time.
Press and hold
+
A graphical representation of the coil positions is shown as a
circular diagram, with shaded areas representing the phases
and boxes for each of the coils (these are labelled l1, l2 and
l3).
Moving the coils in proximity to the conductors will change
their positions on the diagram. If coils are correctly separated
they should each be positioned in their own shaded area.