STEP 3.
WIRELESS SIREN
OFF
ON
STEP 5.
SYSTEM REGISTRATION & MONITORING SET-UP
Now that the physical installation is complete you will need to create a SecureNet
Alarm Monitoring Account.
Please visit www.watchguardalarms.com.au and click on the 'Create Account'
button and then follow the instructions.
If you do not have internet access, please call 1300 653 533 to complete a phone
registration. Once you have registered your installation is complete.
Set the Main Control Unit
into wireless siren auto
test mode by setting DIP
switches 1 and 5 to ON.
Turn the external siren
keyswitch to ON and then
hold the siren in the
desired mounting position.
When this mode is entered
the strobe on the siren will
flash every 5 seconds, and
the main unit will beep out
the signal strength every 5
seconds. Note that the
siren must be moved until
a minimum of 3 beeps is
heard from the main unit.
Reset dipswitches to off.
Mount the siren if wireless
siren
auto
test
was
successful.
Drill
mounting
holes,
(7mm
diameter,
25mm
minimum in depth) into
the chosen wall. (If brick,
use the green star plugs &
press one into each hole.
Now make a 12 mm
diameter hole and push the
wires through the wall and
up into the ceiling for
power.
Screw the top 2 siren
screws half way in and
place the unit onto the
wall supporting itself from
the top 2 screws, then
screw in and tighten the
bottom
two
mounting
screws
then
finish
tightening the top two
screws. Run the power
supply wire through the
roof to the closest power
point,
connect
power
supply and switch on.
STEP 4.
OPERATION
(Ensure main unit keyswitch is ON)
Press
Button 1

AWAY mode

Press once to arm the system in
normal AWAY mode. The internal
screamer
intervals for the 30-second exit delay
and the outside siren will beep once.
The strobe will flash once.
STAY mode
Press twice within 3 seconds to arm
the system in STAY mode. The
internal screamer will beep at 2-
second intervals for the 30-second
exit delay and the outside siren will
give a low tone beep after the second
press.
Panic mode
Press and hold (3 seconds) to
activate PANIC mode, the outside
siren will sound and the strobe will
flash but the internal screamer will
not sound.
Press
Button 2
DISARMING
Press once to disarm the system. The
siren will beep twice. The strobe will
flash for 5 seconds.
Press
Buttons 1 & 2 Together
QUIET ARMING and
DISARMING
(i.e. No External Siren Beeps)
quiet
For
DISARMING press both buttons
together, once
For quiet STAY arming press both
buttons
twice within 3 seconds.

IMPORTANT NOTE:

When testing the operation of the system you will NOT
be contacted by SecureNet if the alarm is triggered but
then cancelled (disarmed) within 30 seconds.
will
beep
at
1-second
AWAY
arming
or
together
simultaneously,