The product counts accumulated water supplying time for each of consumable parts as a rough
indication for replacement since each consumable part has a total water supplying amount before
its use life. When the accumulated water supplying time is reached, the consumable part
replacement error is triggered. Replace the consumable part with the error, and then follow the
procedures below to reset the accumulated water supplying time count.
Consumable part replacement error and resetting the accumulated water supplying time
counter (when an alarm is triggered)
※ Be sure to reset the unit after having replaced consumable parts. When the error is for the
replacement of multiple consumable parts, first replace all consumable parts before resetting.
※ During the alarms for multiple consumable parts, the alarms will be reset in the order below.
Repeat operations for the number of the alarms.
Resetting order:
※ Alarm may be triggered again if water quality will not improve.
6. Maintenance procedures

Resetting after replacement of consumable parts

① Turn the ELB on the right side of the main unit
to "ON(|)".
② Press the POWER key.
・ For
consumable part
Press the CLR key on the operation panel
longer to sound the acceptance tone when
the alarm indication is reset and you can start
normal operation.
・ For the replacement error of multiple
consumable parts
③ Pressing the CLR key on the operation panel
longer to sound the acceptance tone and
the
④ Pressing the CLR key on the operation panel
longer again to sound the acceptance tone
and the
⑤ Pressing the CLR key on the operation panel
longer again to sound the acceptance tone,
the
can start normal operation.
30
the
replacement
indication will be reset.
indication will be reset.
indication will be reset and you
error