Water Purifier
WL320A/B
Instruction Manual
● Thank you very much for purchasing this Yamato
○ R
Pure Line
WL320A/B.
● Please
read
the
"Warranty" before operating this unit to assure
proper operation. After reading these documents, be
sure to store them securely together with the
"Warranty" at a handy place for future reference.
Warning
Before operating the unit, be sure to read
carefully and fully understand important
warnings in the operating instructions.
Yamato Scientific America Inc.
Santa Clara,CA
LaboCube
R
Pure Line
First edition
"Operating
Instructions"
:
The documents are printed on recycled paper.
and

Advertisement

Table of Contents
loading

Summary of Contents for Yamato Pure Line WL320A

  • Page 1 LaboCube Water Purifier ○ Pure Line WL320A/B Instruction Manual First edition ● Thank you very much for purchasing this Yamato ○ R Pure Line WL320A/B. ● Please read “Operating Instructions” “Warranty” before operating this unit to assure proper operation. After reading these documents, be sure to store them securely together with the “Warranty”...
  • Page 3: Table Of Contents

    Contents 1. Safety precautions ..........................1 Explanation of pictograms ......................... 1 List of symbols ........................... 2 Warning・Caution ..........................3 2. Before operating the unit ........................5 Installing procedures and preparation before operation ..............5 Precautions for installation......................... 6 Installation procedures ........................9 3.
  • Page 4: Safety Precautions

    1. Safety precautions Explanation of pictograms About pictograms A variety of pictograms are indicated in this operating instruction and on products for safe operation. Possible results from improper operation ignoring them are as follows. Be sure to fully understand the descriptions below before proceeding to the text.
  • Page 5: List Of Symbols

    1. Safety precautions List of symbols Warning Danger!: High Danger!: High Danger!: Moving Danger!: Hazard General warnings voltage temperature part of explosion Caution Caution for no Caution for water General cautions Electrical shock! Burning! liquid heating! leak! Poisonous For water only material Prohibitions Do not...
  • Page 6: Warning・Caution

    1. Safety precaution Warning・Caution Warning Never operate the unit in an atmosphere containing flammable or explosive gas Never operate the unit in an atmosphere containing flammable or explosive gas. Otherwise, an explosion or a fire may result since the unit is not explosion-proof. See section “13.
  • Page 7 1. Safety precautions Warning・Cautions Warning Do not adjust the reducing valve. The reducing valve has been set to the water sampling rate of about 1.0L/min(raw water pressure:3×100kPa, reducing valve pressure:0.6×100kPa)at the factory. Never attempt to readjust the reducing valve. If the factory setting of the valve is lost, water leak or reduction of flow may result. Be sure to release the pressure before exchanging consumable parts.
  • Page 8: Before Operating The Unit

    2. Before operating the unit Installing procedures and preparation before operation Warning 1. Be sure to connect the earth wire. ・ Connect the power cord with an earth terminal included to an earthed outlet. ・ If a 3-pole power plug with an earth terminal is unavailable, be sure to connect the earth wire (the green core wire of the power cord) to the ground wire or the ground terminal to prevent an electrical shock accident from earth leakage.
  • Page 9: Precautions For Installation

    2. Before operating the unit Precautions for installation 3. Never operate the unit in an atmosphere containing flammable or explosive gas. ● Never operate the unit in an atmosphere containing flammable or explosive gas. Since This product is not of an explosion-proof structure. Accordingly, when the electric leakage breaker on the right side of the unit is turned ON(|)/OFF(○) and in the course of operation, arc may occur, possibly causing fire and explosion.
  • Page 10 2. Before operating the unit Precautions for installation 7.Connecting the power cord ● Connect the attached power cord to the power cord socket. Confirm that the Electric leakage breaker on the right side of the main body is OFF (○), and connect the power cord plug to the socket outlet.
  • Page 11 2. Before operating the unit Precautions for installation 9. Installation The model WL320A is a desktop type The model WL320B is a floor type ●The model WL320A is a desktop type with rubber feet. ●The model WL320B is a floor type with caster wheels.。 10 Be sure to keep the raw water pressure from water supply within the specified range.
  • Page 12: Installation Procedures

    2. Before operating the unit Installation procedures 1.Always connect the feed water hose firmly. ● Take out the feed water hose set (connector main body, feed water hose) from accessories to the main body. Install the main body on a horizontal stable place close to the faucet and sink.
  • Page 13 2. Before operating the unit Installation procedures 3. Carry out connection on the main body side. (1) Remove rubber cap from the water inlet plug ⑧. Feed water hose Main body side With the sleeve slid in the direction indicated with arrow, and insert the main body water ⑧...
  • Page 14 2. Before operating the unit Installation procedures 6.Connect the ion exchange resin cartridge firmly. ●Install the ion exchange resin cartridge as follows: (1) Confirm that the electric leakage breaker on the right side of main body is OFF (○) and that the faucet is closed.
  • Page 15 2. Before operating the unit Installation procedures ●Connect ion exchange resin cartridges (CPC-C and CPC-E) as follows. Remove a rubber cap from the inlet and outlet of each ion exchange resin cartridge. Coupler (1)Push the one-touch joint with a ( Back、OUT) One-touch joint mark into the outlet(right side) on the ion exchange resin cartridge in the back until it...
  • Page 16 2. Before operating the unit Installation procedures 7. Connect the pretreatment cartridge firmly. ● Connect the pretreatment cartridge and the ion exchange resin cartridge as follows. Remove a cap from the inlet and outlet of pretreatment cartridge. (1) Connect the pretreatment coupler connected to the front ion exchange resin cartridge IN to the OUT of the pretreatment cartridge.
  • Page 17 2. Before operating the unit Installation procedures 8.Connect the membrane filter firmly. ● Install the membrane filter as follows. ● Connect firmly. Otherwise, water may leak through the threaded portion. (1) Select the membrane filter and seal tape from accessories of the main body. (2) Pay attention to the arrow direction of membrane filter and wind the seal tape, clockwise as viewed from the winding side, by two to three turns while giving slight tension.
  • Page 18 2. Before operating the unit Installation procedures 9.Connect the water sampling hose to the main unit. ●Follow the steps below to install the water sampling hose. ●Be sure to connect the hose to prevent water leak at the connection with the piping. (1) Push the water sampling hose into the water sampling port on the back straight and completely while holding the one-touch coupler by hand Water...
  • Page 19 2. Before operating the unit Installation procedures 10.Fix the membrane filter onto the water sampling base. ●Install the membrane filter onto the water sampling base following the steps below. (1) Direct the arrow on the membrane filter as shown in the drawing and then pinch the filter to which the water sampling hose is connected from above.
  • Page 20 The model WL320B is a caster wheel type. When installing it, fix it using the caster wheel included. Caster wheel Caster tray...
  • Page 21: Names And Functions Of Parts

    3. Names and Functions of Parts Main unit The A type has rubber feet while the B type has caster wheels on the main unit. exchange resin cartridge Cartridge: CPC-N x 2 Product code: CPCN30010 ※ Change 2 cartridges simultaneously |: [ON] ○:[OFF] Water quality...
  • Page 22: Water Sampling Base

    3. Names and Functions of Parts Water sampling base One-touch couple r 手 Hose band Flexible arm Suction hose Hose band Membrane filter suction port on the back Clip of the unit Base Piping diagram ⑦ ⑤ ⑥ ② ① Water Main port suction...
  • Page 23: Operation Panel

    3. Names and Functions of Parts Operation panel ⑦ ② ③ ⑧ ① ④ ⑤ ⑥ Nomenclature Control/operation ① Power key Turns ON/OFF power supply to the controller. ② Water quality display Displays the quality of deionized water. Displays errors, replacement timing of consumable ③...
  • Page 24: Operation Method

    4.Operation Method Pre-start preparation and checks Be sure to check again before use. (1)Confirmation of water feed ・Confirm that the feed water hose is firmly connected. ・Open the faucet. ・Confirm that the connection of feed water hose is free from water leakage. (2)Confirmation of power supply ・Check if the power cord is connected to the appropriate socket outlet.
  • Page 25: Sampling The Deionized Water

    Sampling the deionized water Sampling the deionized water ① Press the PUSH key. Sampling of deionized water is possible. Sampling continues even when the key is released. ● n-operation lamp ON ● The information Display provides animated display during sampling. Animated indication during sampling ※...
  • Page 26: Water Quality And Water Quality Display

    4.Operation Method Water quality and water quality display Measuring the electric conductivity (conductivity) The Water Quality Display of operation panel shows the electric conductivity at the outlet of ion exchange resin cartridge. Use the displayed reading as a guideline to determine the cartridge replacement timing.
  • Page 27: Water Quality Characteristics Data (Reference)

    4.Operation Method Water quality characteristics data (reference) Use life of an ion exchange resin cartridge(reference) 比抵抗値 Specific resistance R TOC value TOC値 1000 1200 1400 1600 Total water amount(L) ※Tap water in Yamanashi pref. ・・・Specific resistance R: approx. 0.005×10 Ω・m TOC:Approx.300ppb Initial water quality characteristics after replacing an ion exchange resin cartridge (reference)
  • Page 28: Useful Functions

    5. Useful Functions List of options Name of material Article Compatible Remarks model Feed water port unit 253686 WL320A/B Used when the raw water feed port is not equipped with (OWH10) the sink. Install a faucet to the water supply line. 253764 Screw type For the use, refer to the “List of connection patterns with Feed water port coupler the feed water port”...
  • Page 29 5. Useful Functions Optional function list List of patterns of connection with the feed water port Standard feed water hose cap Connection when the Feed water port coupler (with stopper) ・・・ water pipe is provided joint A(OWG34) Connection with the chemical with G1/2 male threads faucet (faucet...
  • Page 30: Setting Of The Remote Sampling Functions (Optional)

    5. Useful Functions Setting of the remote sampling functions (optional) This is a function to enable sampling without operating the sampling key by means of the remote signal. Connect terminals Connect to the remote sampling input terminal in (Terminal screw size:M4) the upper portion of the left side of main body.
  • Page 31: Maintenance Procedures

    6. Maintenance procedures Maintenance and inspection Maintenance and inspection timing (To ensure stable operation of the product, be sure to carry out daily inspection.) Timing Remarks Maintenance・inspection items Replacing the ion exchange Treatment capacity: When resin cartridge About 1200L for the raw water of 200 ×10 (see P.11 and12) appears...
  • Page 32: Before Replacement Of The Ion Exchange Resin Cartridge And The Pretreatment Cartridge

    6. Maintenance procedures Before replacement of the ion exchange resin cartridge and the pretreatment cartridge Relieving the internal pressure before replacement of consumables ① Turn ON the power switch on the right side of main body. ② Place a beaker at the sampling port. ③...
  • Page 33: Resetting After Replacement Of Consumable Parts

    6. Maintenance procedures Resetting after replacement of consumable parts The product counts accumulated water supplying time for each of consumable parts as a rough indication for replacement since each consumable part has a total water supplying amount before its use life. When the accumulated water supplying time is reached, the consumable part replacement error is triggered.
  • Page 34 6.Maintenance procedures Resetting after replacement of consumable parts The total amount of water supply is specified for each of consumable parts and the unit counts accumulated water supplying time to monitor the use life of each consumable part. Note, however, that we recommend replacing pretreatment cartridges or membrane filters at least once in six months or one year irrespective of their frequency of usage before the consumable part replacement error appears on the unit since they are subject to clogging.
  • Page 35: Clean The Feed Water Hose Filter

    Replacing the water supply solenoid valve and the reducing valve Replacing the water supply solenoid valve and the reducing valve ・Be sure to use the water supply solenoid valve and the reducing valve specified by Yamato. ・The rough interval for replacing the piping hose is five years.
  • Page 36: When The Unit Is Not To Be Used For A Long Time Or When Disposing

    7. When the unit is not to be used for a long time or when disposing Alarm 1.For disposal ● Dispose of the product as a waste. ● When disposing of, do not leave the product in a place where children gather to play. 2.
  • Page 37 7. When the unit is not to be used for a long time or when disposing Requests in case of disposal Name of principal parts Material Principal components of piping system Feed water hose Vinyl chloride Piping hose Vinyl chloride (transparent) Water sampling hose Polyurethane...
  • Page 38: Troubleshooting Guide

    8.Troubleshooting Guide Display and contents How to take the countermeasure In case of display of the error as follows in the Error・Consumables Replacement Display, take note of the content of error. Turn OFF(○) the electric leakage breaker on the right side of main body and close the faucet.
  • Page 39 8. Troubleshooting Display and contents Alarm Display Conditions Countermeasure Replace the ion exchange resin. (See P. 11) Continue sampling till the water Water quality of deionized quality is improved and the CPC Notifying water: display disappears after exchange resin replacement (automatic reset) 1×10 S/m or more replacement...
  • Page 40: Repairing Procedure

    8. Troubleshooting Repairing procedure Measures to be taken in case of display of water leakage, 1. Imperfect connection of the water supply port coupler, the one-touch joint of the ion exchange resin cartridge, and the preprocess coupler of the pretreatment cartridge. ※...
  • Page 41: Check List

    8. Troubleshooting Check list Countermeasures Symptom Probable cause ● Imperfect connection of the power Reconnect the power cord. cord and the power socket. Turn the overcurrent switch inside ● Overcurrent switch OFF Power will not turn the main unit door to “ON(|)”. ●...
  • Page 42: After Sales Service And Warranty

    9. After sales service and warranty When requesting a repair When requesting a repair If any trouble occurs, immediately stop operation, turn the electric leakage breaker off(○), disconnect the power plug and contact your dealer or our sales office. Information necessary for requesting a repair ●...
  • Page 43: Specification

    10.Specification Model WL320A WL320B Legs of main unit Rubber legs Caster Sampling method Ion exchange Feed water type One-touch coupler water supply connection resin hose Sampled pure water JIS K 0557 A4 deionized water Sampling rate About 1L/min deionized water, taken continuously method ※2 exchange resin...
  • Page 44: Electric Circuit Diagram

    11.Electric Circuit Diagram Wiring diagram...
  • Page 45: Parts Symbols For Wiring Diagram

    11.Electric Circuit Diagram Parts symbols for wiring diagram ・Standard parts Symbol Name of part Symbol Name of part Power socket(AC250V、15A) Switching power supply(Dc output: POWER 24V、1.3A) Feed water electromagnetic valve Circuit protector AC250V、3A) Terminal board(AC250V、20A) Sampling electromagnetic valve CONT Planer substrate Water quality sensor Display substrate Leak sensor...
  • Page 46: Replacement Parts List

    12.Replacement Parts List Code № Name of part Specifications Manufacturer Ion exchange resin cartridge CPCN30010 CPC-N Yamato Scientific (one included)※ 253099 PWF-1 Preprocess cartridge Yamato Scientific 9020010004 MFRL727 Membrane filters (two included) Yamato Scientific Hose in pipe 3040060005 φ9×φ13 Yamato Scientific (Flexible hose)...
  • Page 47: List Of Dangerous Materials

    13. List of dangerous materials Never use an explosive substance a flammable substance or a substance containing them for this device. ①Nitroglycol, glycerine trinitrate, cellulose nitrate and other explosive nitrate esters ②Trinitrobenzen, trinitrotoluene, picric acid and other explosive nitro compounds ③Acetyl hydroperoxide, methyl ethyl ketone peroxide, benzoyl peroxide and other organic peroxides ④Metallic azide, including sodium azide, etc.
  • Page 48: Standard Installation Manual

    14. Standard installation manual * Install the product according to the following: (Confirm separately for optional items or special specifications) Installation Judg Model Serial number Date Installation mgr. mgr.(company name) ment TOC No. Reference page of the operating Item Implementation method Judgment №...
  • Page 49 Be sure to use the unit strictly following the handling and operating instructions in this operating instruction. Yamato Scientific Co., Ltd. assumes no responsibility for an accident or a malfunction caused by use of this product in any way not specified in this operating instruction.