EVAP TEMP SENSOR SHORTED LOW (ACTIVE) —
TEST
4
Turn the ignition off.
Disconnect the Automatic Temperature Control (ATC) C1 harness connector.
Disconnect the Evaporator Temperature Sensor harness connector.
Measure the resistance between the Evaporator Temperature Sensor Signal circuit
and the Sensor Ground circuit.
Is the resistance below 10k ohms?
Yes → Repair the Evaporator Temperature Sensor Signal circuit for a
→ Replace the Automatic Temperature Control (ATC) in accordance
No
ACTION
short to the Sensor Ground circuit.
Perform BODY VERIFICATION TEST - VER 1.
with the Service Information.
Perform BODY VERIFICATION TEST - VER 1.
157
HEATING & A/C
Continued
APPLICABILITY
All