Abnormal high, Low temperature alarm setting method
▶ What is abnormal alarm function? It is an alarm function notifying it to user in case that the temperature of
incubator inside raised or decreased abnormally.
※ How to Set
5Sec.
* Max. abnormal temp. alarm limit [0.0 ~ 5.0
* Min. abnormal temp. alarm limit [0.0 ~ -5.0
Daily Temp. Range(D.T .G) setting method
▶ Press
TEMP. GAP lamp and turn ON daily temperature range.
And turn off run lamp to turn OFF daily temperature range.
[Default Setting : OFF]
▶ Daily temperature range (D.T.G)?
It is a function artificially making the highest time zone of
temperature by sun at the natural condition, and it is a
function that can raise the incubation success rate of
the optimal incubation environment by raising temperature
at the fixed time zone.
When D.T,G function operates, TEMP. GAP lamp flickers.
D.T,G function is 1.5
set temperature once a day for 3 hours.
How to change Cels. & Fahr.
▶ Press
and press
on temperature display window to change it.
DIGITAL INCUBATOR
3. Incubation
Set required
high range with
UP / DOWN button
button pressing
(2.7
) higher than the existing
button and
button at the same time
button at the state that CA was displayed
Repeat
Insect Incubator Rcom Max 90 User Manual
Save setting and
pass to
low humi. set
(0 ~ 9
) Default Setting : 0℃]
(0 ~ -9
) Default Setting : 0
button to turn on
(4) Abnormal high, Low temperature alarm setting method
(5) Daily Temperature Range(D.T.G) setting method
(6) How to change Centigrade & Fahrenheit
Set required
low range with
UP / DOWN button
]
( ① Keep pressing the button)
TEMP +
TEMP -
( ① Keep pressing the button)
Save setting and
pass to current
temp. & humi.
indication