Cooling module fundamentals
FRONT
FRONT
FRONT
The following output displays on a Virtual Services Platform 9010 with a second generation module:
Fan Trays Info :
Zone Info :
FRONT zone :
Mode : NORMAL
Mode Status : Normal
Highest Temperature : 53 C
Extended Zone :
FPGA Highest Temperature : 67 C
FA Highest Temperature : 72 C
REAR zone :
Mode : NORMAL
Mode Status : Normal
Highest Temperature : 0 C
Fan Info :
Tray
CardType
FAN 1
FAN 2
Zone
FRONT
FRONT
FRONT
FRONT
FRONT
FRONT
FRONT
FRONT
Use the data in the following table to understand the output for the show sys-info command on
the Virtual Services Platform 9010.
Value
FRONT zone:
For the 9010 module, the front
zone consists of two fan trays with
four fans in each tray, which cool
the CP and I/O modules.
Installing Cooling Modules in Avaya VSP 9000
20
FAN 2
2
FAN 2
3
FAN 2
4
Serial#
9010CM
LBNNTMC29Y004F
9010CM
LBNNTMC29Y0043
Tray
Unit
FAN 1
1
FAN 1
2
FAN 1
3
FAN 1
4
FAN 2
1
FAN 2
2
FAN 2
3
FAN 2
4
Mode:
Mode Status:
Highest Temperature
Comments? infodev@avaya.com
OK
OK
OK
Part#
EC1411012-E6
EC1411012-E6
Status
OK
OK
OK
OK
OK
OK
OK
OK
Description
Each zone operates in either
normal mode or alarm mode.
Normal Mode – All the fans are
healthy and no temperatures
exceed the warning threshold.
Alarm Mode – Indicates fan or fan
tray failures or temperature
exceed the warning threshold.
Specifies the highest temperature
reached in the front zone.
Table continues...