Avaya 9012FC IO Manual
Avaya 9012FC IO Manual

Avaya 9012FC IO Manual

Installing cooling modules for virtual services platform 9000
Table of Contents

Advertisement

Quick Links

Installing Cooling Modules in Avaya
Virtual Services Platform 9000
Release 4.0
NN46250-302
Issue 05.05
March 2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9012FC IO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Avaya 9012FC IO

  • Page 1 Installing Cooling Modules in Avaya Virtual Services Platform 9000 Release 4.0 NN46250-302 Issue 05.05 March 2015...
  • Page 2 APPLICABLE TO ANYONE WHO DOWNLOADS, USES AND/OR written consent of Avaya can be a criminal, as well as a civil offense INSTALLS AVAYA SOFTWARE, PURCHASED FROM AVAYA INC., under the applicable law.
  • Page 3 Hosted Service notices and articles, or to report a problem with your Avaya product or Hosted Service. For a list of support telephone numbers and contact addresses, go to the Avaya Support website: http://support.avaya.com (or such successor site as designated by Avaya), scroll to the bottom of the page, and select Contact Avaya Support.
  • Page 4: Table Of Contents

    Removing the I/O cooling module for the VSP 9012 .............. 55 Installing the SF cooling module for the VSP 9012 .............. 56 Removing the SF cooling module for the VSP 9012 Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 5 Contents Chapter 6: Translations of safety messages................ 58 ............ 58 Class A electromagnetic interference warning statement ................ 59 Electrostatic discharge caution statement ................ 60 Cooling module fan safety danger statement Glossary........................... 62 March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 6: Chapter 1: Introduction

    • For information about environmental specifications for the chassis, see Installing the Avaya Virtual Services Platform 9000, NN46250-304. • For information about Installing the 9048XS-2 I/O module, see Release Notes for Avaya Virtual Services Platform 9000, NN46250-401. Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 7: Related Resources

    Avaya Mentor videos provide technical content on how to install, configure, and troubleshoot Avaya products. About this task Videos are available on the Avaya Support website, listed under the video document type, and on the Avaya-run channel on YouTube. Procedure •...
  • Page 8: Support

    Searching a documentation collection On the Avaya Support website, you can download the documentation library for a specific product and software release to perform searches across an entire document collection. For example, you can perform a single, simultaneous search across the collection to quickly find all occurrences of a particular feature.
  • Page 9: Chapter 2: New In This Release

    Chapter 2: New in this release The following sections detail what is new in Installing Cooling Modules in Avaya Virtual Services Platform 9000, NN46250-302, for Release 4.0. Features See the following sections for information about feature changes. Second generation I/O modules Temperature information is updated to reflect the introduction of second generation I/O modules.
  • Page 10: Chapter 3: Cooling Module Fundamentals

    Chapter 3: Cooling module fundamentals This chapter describes the Avaya Virtual Services Platform 9000 cooling modules for the Virtual Services Platform 9010 and the Virtual Services Platform 9012. The Virtual Services Platform 9010 requires only one type of cooling module and the Virtual Services Platform 9012 requires an Input Output (IO) cooling module and a Switch Fabric (SF) cooling module.
  • Page 11 46. For more information about the power specifications of the Virtual Services Platform 9010 cooling module, see Installing the Avaya Virtual Services Platform 9000, NN46250-304. The following figure shows the Virtual Services Platform 9010 cooling module in a partially open position.
  • Page 12: Front Panel Led For The 9010Cm Cooling Module

    The LED flashes faster when only 5 seconds remains. Fault There is no power to the controller or the controller module has failed. Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 13: Airflow In The Virtual Services Platform 9010

    Cool air inlet at the front of the chassis. Power supply air inlet. Hot air exhaust for the CP and I/O modules at the rear of the chassis. Table continues… March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 14: Temperature Alarms

    74 °C At 70 °C, the system At 75 °C, the system triggers the alarm when shuts down the module the module exceeds the when the module Table continues… Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 15 The module does not go online again unless you re-enable the module. After CP, SF, or I/O modules shut down, use the sys power slot {slot[-slot][,...]} command to bring the module back online. March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 16 The following figure shows the baseboard component of a second generation I/O module on the left and the PIM component of a second generation I/O module on the right. Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 17 The following example shows command output for both first and second generation I/O modules. Switch:1#show sys-info temperature Temperature Info : Slot Zone-1 Zone-2 Zone-3 Zone-4 Zone-5 Highest Lowest Alarm Shutdown Temp Temp Temp Temp Temp Temp Temp Threshold Threshold March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 18 Shutdown Threshold Specifies the temperature, when exceeded by one degree, that causes the system to shutdown the module by removing power from the slot. Extended Temperature Zones Table continues… Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 19 Serial# Part# FAN 1 9010CM EC1411012-E6 FAN 2 9010CM EC1411012-E6 Zone Tray Unit Status FRONT FAN 1 FRONT FAN 1 FRONT FAN 1 FRONT FAN 1 FRONT FAN 2 March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 20 CP and I/O modules. Alarm Mode – Indicates fan or fan tray failures or temperature exceed the warning threshold. Highest Temperature Specifies the highest temperature reached in the front zone. Table continues… Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 21 FRONT FAN 2 Unit 3 Specifies the status of a fan in the second cooling module. FRONT FAN 2 Unit 4 Specifies the status of a fan in the second cooling module. March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 22: Virtual Services Platform 9012

    Two 9012FCHS I/O cooling modules The following table describes non-supported configurations. Avaya allows the following configurations for short time periods to install or swap I/O cooling modules. I/O cooling First generation I/O modules expected...
  • Page 23: 9012Fchs I/O Cooling Module

    I/O cooling modules. 9012FCHS I/O cooling module Avaya supports the high-speed 9012FCHS Input/Output (I/O) cooling module for the Avaya Virtual Services Platform 9012 chassis to support the high-density 10 Gigabit Ethernet, as well as the 40 Gigabit Ethernet, I/O modules.
  • Page 24 Table 8: 9012FCHS cooling module dimensions Width Length Depth Weight 9012FCHS I/O 9.875 inches 23.5 inches 1.125 inches 9 pounds cooling module (250.8 millimeters) (596.9 millimeters) (28.6 millimeters) (4.08 kilograms) Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 25: 9012Fc I/O Cooling Module

    The I/O cooling modules are hot swappable. You can replace them, one at a time, without turning off the Virtual Services Platform 9000. The following figure shows the cooling module for the Virtual Services Platform 9012. March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 26: Front Panel Led For The 9012Fc And 9012Fchs I/O Cooling Modules

    The 9012FC and the 9012FCHS I/O cooling modules for the Virtual Services Platform 9012 provides a bicolor LED on the front panel to indicate the fan status. The following table provides a description of the LED colors: Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 27: 9012Rc Sf Cooling Module

    The following figure shows the SF cooling module for the chassis. Figure 5: SF cooling module partially removed The following table provides the dimensions for the 9012RC SF cooling module. March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 28: Airflow In The Virtual Services Platform 9012

    Airflow in the Virtual Services Platform 9012 Airflow in the Virtual Services Platform 9012 is from left-to-right (as viewed from the front) for I/O modules and front-to-back for switch fabric cards and power supplies. Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 29 Description I/O module air inlet Power supply fan air inlet I/O module air exhaust 9012FC or 9012FCHS cooling modules Switch Fabric module air inlet Airflow – left to right March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 30 Virtual Services Platform 9012. The 9012 cooling modules provide air movement and have an adjustable fan speed that depends on the system temperature. Figure 7: 9012 cooling module Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 31 Do not place the Virtual Services Platform 9012 directly against a wall, equipment, or other obstruction. Avaya recommends 36 inches (91 centimeters) of free space in both the front and back of the machine, and 6 inches (15.2 centimeters) on each side extra. Depending on the circumstances, increase the free space at the side to allow for more airflow or cool airflow into the Virtual Services Platform 9012.
  • Page 32: Temperature Alarms

    Green Alarm clears after the — temperatures of the modules are at 58 °C. Table continues… Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 33 Zones 1, 2, and 3 are inlet air sensors and 4 and 5 are outlet air sensors. The SF module has two temperature sensors and the CP module has four temperature March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 34 The following figure shows the baseboard component of a second generation I/O module on the left and the PIM component of a second generation I/O module on the right. Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 35 Services Platform 9010 and the Virtual Services Platform 9012. The following example shows command output for both first and second generation I/O modules. Switch:1#show sys-info temperature Temperature Info : March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 36 This information applies only to second generation modules. FPGA Specifies the temperature of the FPGA sensors. A value of -- indicates that this sensor is not available on this slot. Table continues… Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 37 9012RC SF-FAN 2 9012RC Zone Tray Unit Status FRONT IO-FAN 1 FRONT IO-FAN 1 FRONT IO-FAN 1 FRONT IO-FAN 1 FRONT IO-FAN 1 FRONT IO-FAN 1 FRONT IO-FAN 1 March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 38 SF-FAN 1 REAR SF-FAN 2 REAR SF-FAN 2 Use the data in the following table to understand the output for the show sys-info command on the Virtual Services Platform 9012. Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 39 Specifies the status of each of the fans in the first cooling module. FRONT IO-FAN 2 (1-8) Specifies the status of each of the fans in the first cooling module. Table continues… March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 40: Data Center Floor Plan

    The cold aisles can have a raised floor, which consists of tiles with perforations to allow cold air to enter the devices. Figure 11: Data center floor plan of hot and cold aisles The following table describes the layout of the data center in the preceding figure. Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 41: Optimizing Cooling In A Data Center

    Virtual Services Platform 9012 chassis. Baffles are added to redirect air from the side to the back of the chassis into the hot aisles. Cooling floor tiles are relocated near the cool air intake to improve cooling. March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 42: Virtual Services Platform 9012 Placement In The Rack

    If you place each Virtual Services Platform 9012 in a row from left to right, the chassis to the left discharges hot air into the cool intake of the chassis to the right. Installing Cooling Modules in Avaya VSP 9000 March 2015...
  • Page 43: Other Cooling Considerations

    Consider hot airflow from other pieces of equipment in the vicinity of the Virtual Services Platform 9012. Computers, Telecommunications, and other equipment located above and below the Virtual Services Platform 9012 can discharge hot air onto the chassis. Table continues… March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 44: Protecting Modules

    Clearance Do not place the Virtual Services Platform 9012 chassis directly against a wall, equipment, or other obstruction. Avaya recommends 36 inches (91 centimeters) of free space in both the front and back of the machine and 6 inches (15.2 centimeters) on each side).
  • Page 45 • Do not leave slots open. Fill all slots with modules or filler modules to maintain safety compliance, proper cooling, and EMI containment. • Do not over tighten screws. Tighten until snug. Do not use a power tool to tighten screws. March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 46: Chapter 4: Cooling Module Installation And Removal For The Vsp 9010

    Before you can install or remove a power supply or cooling module, you must remove the air inlet cover from the chassis. Procedure 1. Grasp the cover on each side. 2. Lift the cover up and away from the chassis. Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 47: Installing The Cooling Module For The Vsp 9010

    Install the cooling modules horizontally in the front of the Virtual Services Platform 9010. Before you begin • Remove the air inlet bezel. • Acquire the following items: - Phillips #2 screwdriver - Antistatic wrist strap March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 48 4. Rotate the action levers until the levers are parallel with the module. 5. Use the screwdriver to tighten the two captive screws to the left and right of the cooling module to secure the cooling module to the chassis. Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 49: Removing The Cooling Module From The Vsp 9010

    You have 15 seconds to remove the cooling module before the fans begin to spin back up. The LED flashes faster when only 5 seconds remains. March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 50 When you remove a cooling module, allow time for the fans to spin down before you fully withdraw the cooling module. Be careful to keep your fingers out of the fan blades, as shown in the following figure. Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 51 Keep the failed cooling module installed in the chassis until you have a replacement module or keep a replacement cooling module available for immediate replacement. March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 52: Chapter 5: Cooling Module Installation And Removal For The Vsp 9012

    I/O cooling module to be installed before you install the 9048XS-2 module. Procedure 1. Locate the bay where you want to install the cooling module. 2. Slide the cooling module into the chassis. Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 53 The connector at the rear of the cooling module must connect to the midplane. 5. Release the pin on the cooling module. 6. Verify that the cooling module LED light is green. March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 54: Removing The I/O Cooling Module For The Vsp 9012

    2. Pull the module out of the chassis until it is partially removed, as shown in the following figure. Allow time for the fans to spin down. Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 55: Installing The Sf Cooling Module For The Vsp 9012

    2. Grasp the handle on the cooling module and slide the module into the chassis until the module is flush with the side of the chassis. The connector at the rear of the cooling module must connect to the midplane. March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 56: Removing The Sf Cooling Module For The Vsp 9012

    Remove the SF cooling module from the slot to remove it. You can hot swap the cooling modules. Procedure 1. Loosen the captive screws that secure the cooling module to the midplane. Danger: Risk of personal injury Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 57 Allow time for the fans to spin down. 3. Continue to slide the module out of the chassis and use your free hand to support the weight at the rear of the module. March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 58: Chapter 6: Translations Of Safety Messages

    Chapter 6: Translations of safety messages This chapter provides the translation of precautionary notices that you must read and follow for safe operation of the Avaya Virtual Services Platform 9000. Class A electromagnetic interference warning statement Warning: Risk of electromagnetic interference This device is a Class A product.
  • Page 59: Electrostatic Discharge Caution Statement

    Une décharge électrostatique (DES) peut endommager les circuits électroniques. Ne touchez pas le matériel électronique, à moins de mettre à votre poignet une bande de mise à la masse ou autre dispositif dissipant l'électricité statique. March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 60: Cooling Module Fan Safety Danger Statement

    Wenn Sie ein Kühlmodul entfernen, warten Sie, bis die Lüfter zum Stillstand gekommen sind, bevor Sie das Modul komplett herausnehmen. Achten Sie darauf, dass Ihre Finger nicht die Lüfterflügel berühren. Danger: PELIGRO Riesgo de lesiones Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...
  • Page 61 Rischio di lesion personali In fase di rimozione del modulo di raffreddamento, prima di estrarlo completamente, attendere che le ventole rallentino. Fare attenzione a non avvicinare le dita alle lame della ventola. March 2015 Installing Cooling Modules in Avaya VSP 9000 Comments? infodev@avaya.com...
  • Page 62: Glossary

    Switch Fabric (SF) The SF cooling module is a hot swappable fan tray used to cool the Switch cooling module Fabric (SF) modules in the Virtual Services Platform 9012. (9012RC) Installing Cooling Modules in Avaya VSP 9000 March 2015 Comments? infodev@avaya.com...

This manual is also suitable for:

9012fc9010cm9012fchs9012rc

Table of Contents