Note:
The mangOH Red has two USB connectors:
• CF3 USB is used for SSH connections, AT commands, and firmware downloads.
• CONSOLE_USB is a serial connection used to access the module's console for diagnostic purposes.
5. Move the power select jumper onto the pins closest to the battery connector to select the CF3 USB connector.
(In this guide, power is supplied from the dev machine's USB port to this connector when you connect it in a
later step.)
Note:
OPTIONALLY, if you want to be able to display the target's console messages (diagnostic
messages) and have two available USB ports on your dev machine, follow the instructions in
Access on page
54. This is NOT a required step for this tutorial.
6. Power up the mangOH Red:
a. Use a micro-USB cable to connect the CF3 USB connector to a USB port on the dev machine.
Rev 3 9/21/17
CF3 USB connector
(bottom side of board)
Battery connector
CF3 USB power (jumper on pins
closest to battery connector)
CONSOLE USB connector
12
3.1: Hardware Setup
Console
CF3 USB connector
(bottom side of board)