Baldor DBSC 100 Series Installation And Operating Manual page 18

Hide thumbs Also See for DBSC 100 Series:
Table of Contents

Advertisement

Section
Active Low
Active Low
GNDext
GND
ext
(Sink)
(Sink)
+24VDC
+24VDC
GND
GND
Note:
Note: T h e s e pins are shown wired together. Although this can be done,
These pins are shown wired together. Although this can be done,
each input is usually connected to a switch for individual control of
each input is usually connected to a switch for individual control of
each input condition. Pins 16 and 17 are optional inputs and are
each input condition. Pins 16 and 17 are optional inputs and are
described later in this section.
described later in this section.
A typical wiring control diagram is shown in Figure 3-3.
A typical wiring control diagram is shown in Figure 3-3.
1.
1. C o n n e c t the CREF signal wire to X3-7.
Connect the CREF signal wire to X3-7.
2.
2. C o n n e c t the Enable signal wire to X3-9.
Connect the Enable signal wire to X3-9.
3.
3. C o n n e c t the CW Limit signal wire to X3-10.
Connect the CW Limit signal wire to X3-10.
4. C o n n e c t the CCW Limit signal wire to X3-11.
4.
Connect the CCW Limit signal wire to X3-11.
5.
5. C o n n e c t the Hold signal wire to X3-12 (optional).
Connect the Hold signal wire to X3-12 (optional).
6.
6. C o n n e c t the Reset (Fault Reset) signal wire to X3-13 (optional).
Connect the Reset (Fault Reset) signal wire to X3-13 (optional).
The Reset signal (Fault Reset) can only reset the following fault types: Over
The Reset signal (Fault Reset) can only reset the following fault types: Over
voltage, Under voltage, Resolver fault, or Control Temperature fault.
voltage, Under voltage, Resolver fault, or Control Temperature fault.
Note:
Note: C u r r e n t input for each control input X3-9 to X3-17 is
Current input for each control input X3-9 to X3-17 is
Iin=10mA maximum (for each input).
=10mA maximum (for each input).
I
in
MN1229
MN1229
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Control Signal Wiring Continued
Control Signal Wiring
Figure 3-2 Active HIGH/LOW Relationship
Figure 3-2 Active HIGH/LOW Relationship
Active High
Active High
V
Vext
ext
(Source)
(Source)
GND
GND
+24VDC
+24VDC
3
Continued
X3
X3
Pin 7 - CREF
Pin 7 - CREF
Pin 9 - Enable
Pin 9 - Enable
Pin 10 - CW
Pin 10 - CW
Pin 11 - CCW
Pin 11 - CCW
Pin 12 - Hold
Pin 12 - Hold
Pin 13 - Reset
Pin 13 - Reset
Pin 16 - Machine Input 1
Pin 16 - Machine Input 1
Pin 17 - Machine Input 2
Pin 17 - Machine Input 2
-
5
3–5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dbsc 102Dbsc 105

Table of Contents