• With the LT10 series, 0.001 mm and –0.001 mm (0.0001"
and –0.0001") are not avaible.
• When the addition A+B is chosen the direction for B can
be selected, but its resolution will be the same as that of A.
4. Selecting the start input terminal (terminals) function
(See P60 "6. Terminals I/O".)
: Start function
When the peak-hold is
c h o s e n s e t t i n g t h i s
terminal to "L" (ON) sets
the peak-hold value to
the current value and
r e s t a r t s t h e s t o r i n g
procedure.
: Hold function
When using the current value measuring mode
with the start function, setting this terminal to
"L" (ON) stores the output and display of the
Go/No Go comparison at that point in time.
Note
A t t h i s t i m e , d i s p l a y a n d G o / N o G o
comparison output storage by the DRQ input
for the BCD model and EXT. IN input for the
RS-232C model is invalidated.
Initial settings are now complete for the standard model.
.. Basic model → Returns to the measuring state.
Pressing
MODE
BCD model → Go to section 5-1-2.
RS-232C model → Go to section 5-1-3.
5-1-2. BCD model
Proceeds to the next setting mode from "5-1-1. Basic settings" step 4.
1. BCD logic
Setting the BCD output logic.
"+" is true logic.
"–" is false logic.
Exception : Logic for the DRQ, READY, and alarm
factory-set
2. BCD output format
Setting the BCD output format.
Initial settings are now complete for the BCD model.
Press
(only LT10-105B/205B, LT11-101B/201B)
terminals cannot be changed.
(See P63 "7. BCD output")
: B C D
i s
o u t p u t
according to the DRQ
signal input, and the
resulting status is
held even if the DRQ
signal goes off.
: BCD is output according
to DRQ signal input,
and assumes high-
i m p e d a n c e s t a t u s
when there is no DRQ
signal input.
to return to the measuring state.
MODE
factory-set
factory-set
53