SECTION 3 - MACHINE CONTROLS AND INDICATORS
TO AVOID SERIOUS INJURY, DO NOT OPERATE MACHINE IF ANY CONTROL LEVERS OR
TOGGLE SWITCHES CONTROLLING PLATFORM MOVEMENT DO NOT RETURN TO THE
OFF POSITION WHEN RELEASED.

Ground Control Console

See Figure 3-1., Ground Control Console and Figure 3-2., Ground Control
Console with Machine Safety System Override (MSSO) (CE Only).
NOTE:
The Function Enable switch must be held down in order
to operate Main Boom Telescope, Swing, Main Lift, Jib
Lift, Platform Level Override, Platform Rotate, and
Tower Boom Lift functions.
1. Indicator Panel
The Indicator Panel contains indicator lights that signal
problem conditions or functions operating during machine
operation.
3-2
2. Main Boom Telescope
Provides extension and retraction
of the main boom.
3. Jib Swing
Allows swinging of the jib.
3121734