Power Connector; Connection Of Power Supply; Connection Of Power Connector - Advantech Bivias v2 User Manual

Twin cellular module router
Table of Contents

Advertisement

5.7.2 Power connector PWR
Panel socket 2-pin.
Pin number
Signal mark
1
VCC(+)
2
GND(-)
Power supply for router is required between +9 V to +36 V DC supply. Protection against
reversed polarity without signaling is built into the router. Note: The protection against re-
versed polarity is lost if the negative pole is grounded!
The power consumption during receiving is 2.6 W. The peak power consumption during
data sending is 5.5 W. However, values of consumption can be increased, if some expansion
port is equipped. For correct operation it is necessary that the power source is able to supply
a peak current of 1.2 A.
Circuit example:
The positive pole VCC is marked by a red socket on the power.
All metal parts are connected together with the negative pole of power supply (common pole).
However, the router box may not be connected to the negative pole properly.
Description
Positive pole of DC supply voltage (+9 to +36 V DC)
Negative pole of DC supply voltage
Table 9: Connection of power connector
Figure 11: Power connector
Figure 12: Connection of power supply