Powering up the Switch

An AC power cord is not included with the AC power supply. You can purchase AC power cords for use
in the US and Canada from Extreme Networks or from your local supplier. The cord must meet the
requirements listed in
page 66.
To power up an Extreme Networks switch, do the following.
1
For switches that are connected to AC power, connect the power cord to the AC power input socket
on the switch (or power supply) and to an AC power outlet.
2 For switches that are connected to DC power, do the following:
a Verify that the DC circuit is de-energized.
b Verify that the ground wire is connected to the grounding lug on the rear of the switch.
The grounding lug is identified by the international symbol for earth ground:
c Verify that the DC power input cables are properly connected to the DC power supplies at the
rear of the switch.
d Energize the circuit.
3 When power is connected, verify that the PSU LED turns green.
When the PSU LED has turned green, follow the instructions in
page 42.
If the PSU and RPS LEDs do not turn green, refer to the LEDs topic for your switch model (in
the Switch
on page 57) for troubleshooting information.

Connecting Network Interface Cables

Use the appropriate type of cable to connect the ports of your switch to another switch or router.
Cable Type
CAT5E
CAT6
CAT6A
Working carefully, one port at a time, do the following:
1
Verify that you have identified the correct cable for the port.
2 Use an alcohol wipe or other appropriate cleaning agent to clean the cable connectors; make sure
they are free of dust, oil, and other contaminants.
3 If you are using optical fiber cable, align the transmit (Tx) and receive (Rx) connectors with the
correct corresponding connectors on the switch or the I/O module.
4 Press the cable connectors into their mating connectors on the switch or I/O module until the cable
connector is firmly seated.
5 Repeat step
1
on page 42 through step
modules.
VSP 4900 Series Switches: Hardware Installation Guide
Power Cord Requirements for AC-Powered Switches and AC Power Supplies
Maximum Distance
55 meters
55 meters
100 meters
4
for the remaining cables on this or other switches or I/O
Installing Your Switch
Connecting Network Interface Cables
on
on