Controller And Sensor Pcb (Sensors) - Viessmann Vitocal 300-G Series Installation And Service Instructions Manual

Heat pump with electric drive
Table of Contents

Advertisement

Electrical connection

Controller and sensor PCB (sensors)

Set the required parameters during commissioning:
See page 50 onwards.
Plug
Sensor
F0.1/F0.2
Outside temperature sensor
F0.2/F0.3
Radio clock receiver (on site)
F4
Buffer temperature sensor
F6
Top cylinder temperature sensor
F7
Bottom cylinder temperature sensor
F11
Contact humidistat 24 V
F12
Flow temperature sensor, heating circuit with mixer M2/HC2
F13
System flow temperature sensor with sensor well (downstream of the heating
water buffer cylinder and external heat generator)
F14
Flow temperature sensor, cooling circuit: Heating circuit without mixer
A1/HC1 or separate cooling circuit SKK
F16
Room temperature sensor, cooling circuit
Required for separate cooling circuit SKK
Recommended for heating/cooling circuit without mixer A1/HC1
F20
Boiler water temperature sensor, external heat generator
F27
Flow temperature sensor, secondary circuit for heat pump stage 2
?B
Return temperature sensor, secondary circuit for heat pump stage 2 (if instal-
aJB
(X25.13/
led)
X25.14)
KM-BUS (wires interchangeable)
aVG
Use the KM-BUS distributor (accessories) if several devices are connected.
KM-BUS subscribers (examples):
Mixer extension kit M3/HC3
Remote control: Set the heating circuit allocation on the remote control.
EA1 extension, AM1 extension
Modbus 2 (wires not interchangeable)
sVA
Connection for energy meter of photovoltaic system
J3
Jumper for terminator, Modbus 2
Terminator active (delivered condition)
Terminator not active
J4
Jumper for setting master/slave, Modbus 2
Heat pump control unit is slave
Heat pump control unit is master (delivered condition)
X18
Modbus 1
Viessmann appliances, e.g. ventilation unit Vitovent 300-F
Note
If further Viessmann appliances are to be connected to Modbus 1, plug in the
Modbus distributor (accessories): See "Modbus distributor" installation in-
structions.
X24
Connection, LON communication module (accessories): See installation in-
structions "LON communication module".
X31
Coding card slot
(cont.)
Installation sequence
Type
NTC 10 k
Ω
DCF
NTC 10 k
Ω
NTC 10 k
Ω
NTC 10 k
Ω
NTC 10 k
Ω
NTC 10 k
Ω
NTC 10 k
Ω
NTC 10 k
Ω
NTC 10 k
Ω
Pt500A
(PTC)
Pt500A
(PTC)
31