Siemens RUGGEDCOM RS900F Installation Manual page 46

Hide thumbs Also See for RUGGEDCOM RS900F:
Table of Contents

Advertisement

Chapter 6
Certification
Test
IEC 61000-4-16
IEC 61000-4-17
IEC 61000-4-29
IEC 60255-5
EMC Immunity Type Tests per IEEE 1613
NOTE
The RUGGEDCOM RS900F meets Class 2 requirements for an all-fiber configuration and Class 1
requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires
error-free and interrupted communications.
ESD
Radiated RFI
Fast Transient
Oscillatory
HV Impulse
36
Description
Mains Frequency Voltage
Ripple on DC Power Supply
Voltage Dips and Interrupts
Dielectric Strength
HV Impulse
Description
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
2.5 kV Common Mode @ 1 MHz
1 kV Differential Mode @ 1 MHz
AC Power Ports
2.5 kV Common Mode @ 1 MHz
1 kV Differential Mode @ 1 MHz
Signal Ports
DC Power Ports
DC Power Ports
DC Power Ports
Signal Ports
2 kV (Failsafe Relay Output)
DC Power Ports
AC Power Ports
Signal Ports
5 kV (Failsafe Relay Output)
DC Power Ports
AC Power Ports
2.5 kV Common and Differential Mode @ 1 MHz
2.5 kV Common and Differential Mode @ 1 MHz
Installation Guide
Test Levels
30 V Continuous
300 V for 1 s
30 V Continuous
300 V for 1 s
10%
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
1.5 kV
2 kV
5 kV
5 kV
Test Levels
± 8 kV
± 15 kV
35 V/m
± 4 kV @ 2.5 kHz
± 4 kV
± 4 kV
± 4 kV
2.5 kV Common Mode @ 1 MHz
5 kV (Failsafe Relay)
EMC and Environmental Type Tests
RUGGEDCOM RS900F
Severity Levels
3
3
4
4
3

Advertisement

Table of Contents
loading

Table of Contents