Installation Guide
• IEC 61000-6-2
Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments
• IEC 61850-3
Communication Networks and Systems in Substations – Part 3: General Requirements
• NEMA TS-2
Traffic Controller Assemblies with NTCIP Requirements
Section 6.2

EMC and Environmental Type Tests

The RUGGEDCOM RS900F has passed the following Electromagnetic Compatibility (EMC) and environmental tests.
EMC Type Tests
Test
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
IEC 61000-4-12
EMC and Environmental Type Tests
Description
ESD
Radiated RFI
Burst (Fast Transient)
Surge
Induced (Conducted) RFI
Magnetic Field
Voltage Dips and Interrupts
Damped Oscillatory
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth
Ground Ports
Signal Ports
± 4 kV Line-to-Ground
DC Power Ports
± 2 kV Line-to-Ground
AC Power Ports
± 4 kV Line-to-Ground
Signal Ports
DC Power Ports
AC Power Ports
Earth
Ground Ports
Enclosure Ports
AC Power Ports
100% for 50 Periods
Signal Ports
2.5 kV Common Mode @ 1 MHz
1 kV Differential Mode @ 1 MHz
Test Levels
± 8 kV
± 15 kV
20 V/m
± 4 kV @ 2.5 kHz
± 4 kV
± 4 kV
± 4 kV
± 2 kV
± 1 kV Line-to-Line
± 2 kV Line-to-Line
10 V
10 V
10 V
10 V
40 A/m Continuous
1000 A/m for 1 s
100% for 5 Periods
Chapter 6
Certification
Severity Levels
4
4
x
4
4
4
4
3
4
3
3
3
3
3
35