Service Intervals; Filter Disposal; Reference Conditions; Principal Data - Atlas Copco GA 110 VSD Instruction Book

Table of Contents

Advertisement

9. Remove the plastic bag and reposition the bowl.
7.3

Service intervals

The following service intervals should be observed:
• For filters operating less than 4000 hours per year: 12 months.
• For filters operating 8000 hours per year: 4000 hours or 6 months, whichever comes first.
7.4

Filter disposal

Used filters must be disposed of in an environmentally friendly and safe manner, and in line with the local
recommendations and environmental legislation.
7.5

Reference conditions

Air inlet pressure
Air inlet temperature
Ambient temperature
7.6

Principal data

Maximum compressed air inlet pressure
Minimum compressed air inlet pressure
Minimum compressed air inlet temperature
Maximum compressed air inlet temperature
Maximum compressed air inlet pressure
Minimum ambient temperature
Maximum ambient temperature
Maximum recommended pressure drop
134
A small amount of paint compatible lubricant ( e.g . FOODLUBE EXTREME) may be applied
to screw threads and O-rings to facilitate the assembly.
7 bar(e)
20˚C
20˚C
16 bar(e)
1 bar(e)
1˚C
65˚C
16 bar(e)
1˚C
65˚C
0.35 bar(e)
Instruction book
102 psig
68 ˚F
68 ˚F
232 psig
15 psig
34˚F
149 ˚F
232 psig
34 ˚F
149 ˚F
5 psig
2920 1728 05