Abbreviations _____________________________________ 3 External control The front panel ELK 213 and FIGHTER 1110 / 1115 / 1125 ____________ 13 ELK 213 and FIGHTER 1120 / 1130 / 1135 ____________ 13 Functions on the front panel ELK 213 and F1145 _______________________________ 13...
For Home Owners General General In order to get the ultimate benefit from ELK 213 you should read through these Installation and Maintenance Instructions. ELK 213 is an immersion heater that is primarily intended for installation on double jacketed water heaters, exist- ing immersion heater installations or similar in houses or smaller apartment blocks.
For Home Owners System description System description Principle of operation Abbreviations ELK 213 is an immersion heater intended for heating Circulation pump systems and indirect heating of domestic hot water. The Expansion vessel immersion heater consists of a pressure vessel for an...
This is first done after the cause of the fault has filled with water. Otherwise the tem- been rectified, see “Dealing with malfunctions”. perature limiter, thermostat and the immersion heater can be damaged. Thermostat for immersion heater This thermostat controls the immersion heaters. NIBE ELK 213...
Pipe line between heater and open expansion vessel must be routed upwards and must not be able to be closed. Note! The pipe work must be flushed before the immersion heater is con- nected, so that any contaminants do not damage the components parts. NIBE ELK 213...
Shunt valve Shuntventil on double jacketed water heaters, can be used to heat domestic hot water. This is a favourable solution even for Avstängningsventil Shut-off valve hard water. Recommended thermostat setting is 75 °C Safety valve Säkerhetsventil NIBE ELK 213...
This option El VVB Electrical hot water heater can also be supplemented with a room sensor. This option Flow sensor requires the accessories ELK 213, VST 11 and XTS 20. Level vessel Return temperature sensor Control valve Particle filter SÄV...
Temperature sensor, hot water with the external (BT25) flow sensor. The installed immer- BT25 Temperature sensor, heating medium flow sion heater (ELK 213) is connected automatically when the Expansion vessel energy requirement exceeds the heat pump capacity. This Level vessel option can also be supplemented with a room sensor.
Installation option 7 (air-water heat) SMO 10 FG1* UKV* VXV1 SÄV NIBE air/water heat pump VVB/ACK SMO 10 controls heat pump, immersion heater, circulation Abbreviations pumps, three way valves, etc. The heat pump works with Shut-off valve floating condensing against the heating system and priori- Non-return valve tises hot water charging via the three way valve (VXV1).
Supply on connection is 9 kW in only two stages. Zero from supply is connected to N2 on terminal block (1) With accessory XTS 20, ELK 213 can be controlled exter- nally from FIGHTER 1110 / 1115 / 1125. With accessory AXC 40, ELK 213 can be controlled exter- nally from F1145.
2 kW Vita Bruna Svarta Läge I Mode I N1 N2 L1 L2 L3 Läge II Mode II 7/9 kW in three phases 11/13 kW in three phases 7/9 kW i tre steg 11/13 kW i tre steg NIBE ELK 213...
Note! Check the article number in the SMO, which is installed and follow the corresponding instructions. ELK 213 and SMO 10 (089259) Note! Remove the bridge between N1 and N1 N2 L1 L2 L3 N2 on terminal block 1. Turn the thermostat (4) to max.
Connection, return, R 50 male Draining connection, R 20 female with plug Protective plastic cover Connection area 20* Counter flanges R 50 SMS 2023 DN 50 PN 6 Contactor Contactor 103 Serial number / data plate Accessories NIBE ELK 213...
Max output, electric heater 13 kW (Output on delivery 9 Enclosure class IP 21 Max. permitted total current 10 A for connected apparatus Max operating pressure/ 0.3 MPa (3 bar) design pressure immersion heater E No. 88 350 12 NIBE ELK 213...
Any load monitors block the electrical output. Any circulation pumps become stationary. Poor circulation Any circulation pumps become stationary. If the operating disturbance cannot be rectified by means of the above, an installation engineer should be called. NIBE ELK 213...
= Trestegs belastningsvakt phase by only using the first phase by Three phase load monitor steget genom att steget genom att bridge no. ”2” only using bridge endast använda endast använda no. ”2” bygel nr "2" bygel nr "2" NIBE ELK 213...