Function module for air source heat pump (92 pages)
Summary of Contents for STIEBEL ELTRON SOKI 7 E plus
Page 1
BEDIENUNG UND INSTALLATION OPERATION AND INSTALLATION UTILISATION ET INSTALLATION USO E INSTALLAZIONE BEDIENING EN INSTALLATIE Solar-Kompaktinstallation | Solar compact installation | Installation compacte solaire | Installazione solare compatta | Compacte zonne-installatie » SOKI 7 E plus » SOKI E trend...
Failure to observe this information will result in serious injury or death. wARNING Failure to observe this information may result in serious injury or death. CAUTION Failure to observe this information may result in non-se- rious or minor injury. SOKI 7 E plus | SOKI E trend | 17...
The heat stored in the solar cylinder cannot maintenance unless they are supervised. be transferred if the circulation pump stops. The pump assem- bly includes a thermometer for the flow and return, as well as an optical flow meter. 18 | SOKI 7 E plus | SOKI E trend...
TSK 27 basic ≤ 16 using the screws and rawl plugs supplied. SOL 27 plus ≤ 16 SOL 27 premium ≤ 16 TSK 27 premium ≤ 16 SOKI 7 E plus | SOKI E trend | 19...
Page 5
Refit the flow meter to the pump assembly. f Using the union nut, secure the solar compact installation to the twin nipple that you previously sealed into the cylinder. 20 | SOKI 7 E plus | SOKI E trend...
3 BDF valve "drain" resistant to glycol and temperatures up to 180 °C. 4 water (flushing) / heat transfer medium f Nevertheless, check for leaks during commissioning (pres- 5 Filters sure test). 6 Fill pump SOKI 7 E plus | SOKI E trend | 21...
Page 7
Open BDF valves "fill" and "drain". turning it to the 0° position. f Commission the flushing and filling station and fill the sys- tem with water for flushing. f Flush the system for at least 15 minutes. 22 | SOKI 7 E plus | SOKI E trend...
Set the gravity brake to its operating position (0° position). f Remove the hoses of the flushing and filling station and fit the caps to the BDF valves "fill" and "drain". SOKI 7 E plus | SOKI E trend | 23...
The duty cycle is indicated as a dimensionless ratio with a value from 0 to 1 % or from 0 to 100 %. See chapter "Specification / Pump graphs / Pwm signal logic 2". 24 | SOKI 7 E plus | SOKI E trend...
(000000-0000-000000). the solar thermal system. Ensure that the solar medium is collected in a heat-resistant container. f Open the drain valve at the lowest point of the system. 000000-0000-000000 Made in Germany SOKI 7 E plus | SOKI E trend | 25...
Female thread Rp 3/4 d47 Drain Terminal type Hose connection Diameter d48 Filling Terminal type Hose connection Diameter d50 Expansion vessel male thread G 3/4 A e23 Cylinder return Female thread Rp 3/4 26 | SOKI 7 E plus | SOKI E trend...
Page 12
Female thread Rp 3/4 d47 Drain Terminal type Hose connection Diameter d48 Filling Terminal type Hose connection Diameter d50 Expansion vessel male thread G 3/4 A e23 Cylinder return Female thread Rp 3/4 SOKI 7 E plus | SOKI E trend | 27...
PWM signal logic 2 (solar) Z Power consumption [w] Constant speed X Flow rate [m³/h] Y Delivery head [m] Z Power consumption [w] X Flow rate [m³/h] Y Delivery head [m] Z Power consumption [w] 28 | SOKI 7 E plus | SOKI E trend...
This will not affect warranties issued by any importers. Environment and recycling We would ask you to help protect the environment. After use, dispose of the various materials in accordance with national regulations. SOKI 7 E plus | SOKI E trend | 29...
Page 15
STIEBEL ELTRON GmbH & Co. KG tecalor GmbH Dr.-Stiebel-Str. 33 | 37603 Holzminden Lüchtringer Weg 3 | 37603 Holzminden Tel. 05531 702-0 | Fax 05531 702-480 Tel. 05531 99068-700 | Fax 05531 99068-712 info@stiebel-eltron.de info@tecalor.de www.stiebel-eltron.de www.tecalor.de 4 < A M H C M O = b j c b e f >...