stop and then, after approx. 1 second, entirely
screwed in to maintain tightness.
5.6 Measurement range
Band coding:
The absolute coding of MBA511 enables a max.
measurement range of 20480 mm.
0
+20479999
+1
Position value (-480.00 ... +20.000 mm)
In order to avoid leaps occurring around the maxi-
mum value at the 0 position, this maximum value is
limited to 20 m. This enables recording of a range of
up to -480 mm in negative travel direction.
0
+1999999 -48000
-1
+1
6. Trouble shooting
Below there are some typical errors which may oc-
cur during installation and operation:
• Sensor not or incorrectly connected (for pin con-
nection see chapter 4).
• Tolerance for the gap between magnetic sensor and
magnetic strip not observed over the total travel
distance. Sensor touches strip (see chapter 7).
• Cable squeezed / interrupted / cut by sharp edges.
• Sensor's active side not mounted towards the
magnetic strip (see fig. 8).
• Sensor and magnetic strip have been incorrectly
aligned (see chapter 1).
• Magnetic fields near the measuring surface distort
the measuring values. If required, provide for
adequate screening.
• Wrong measuring values due to EMC interferences
(see chapter 4).
7. List of commands / service mode
Parameters: 19200 Baud, no parity, 8 bit, 1 stop
bit, no handshake
Data code:
ASCII / Hexadecimal
Value range: 2/3 Byte: 0...65535 / 0...± 2
All replies which are confirmed by ">" end with
MSA511+MBA511
Datum 29.07.2015
zero-setting screw
0
+20479999
+1
0
+1999999 -48000
-1
+1
23
"CR" (Dez 13).".
Com.
Length Reply
a
1/13 "MSA511V1.00>" Device type/software version
b
1/4
"ba3f"
cxy
3/4
"xy>"
dxyabcd
7/2
">"
g
1/8
"a3170216"
k
1/0
""
l11100
6/2
">"
p11100
6/2
">"
q
1/2
"31"
s11100
6/2
">"
tx
1/2
">"
u
1/5
"abc"
yx
2/10 "+abcdefg>"
z
1/10 "+abcdefg>"
EEPROM memory array:
Address Size in words Assignment
0
1
1
1
2
1
3
1
4 - 5
2
6
1
Art. Nr. 81105
Description
2x2 byte analogue converter
values (4 byte)
Readout EEPROM values
xy = address 00 ... 63 value re-
turned 2 byte hexadecimal
Stores EEPROM values
xy = address 00 ... 06 abcd 2 byte
values hexadecimal
2 byte offset-0;
2 byte offset-1;
2 byte Ink-Gap;
2 byte absolute zero value
Software reset
Zero-setting (position value is
set to 0)
Starts alignment
1. byte = mode;
2. byte = alignment flag
Set device to default values;
Alignment will be cleared!
default values:
counting direction = up
(in travel direction, increasing
values; see fig. 1)
Zero point value = 0
Determine counting direction
x=0: up
x=1: down
a = quadrant (0 or 1);
b = Pol1-sensor (0 or 1);
c = Pol2-sensor (0 or 1)
x=0: fine value
x=1: rough value
x=2: absolute value 0
x=3: absolute value 1
x=4: position value
position value
offset-0
offset-1
ink-Gap
absolut-null-wert
zero setting value (Long)
counting direction
Änd. Stand 284/15