Setting Obstruction Force; Setting Auto Close; Remote Control; Setting Pedestrian Mode - TdA DKC301DC Installation And User Manual

Sliding gate operator
Table of Contents

Advertisement

DKC301DC SLIDING GATE OPERATOR INSTALLATION AND USER'S MANUAL
desired position. (You also can press OPEN to open the gate, OPEN and CLOSE can be used
to fine adjust the door position.)
5.
Press the SET to confirm the close position, 'II' will be displayed.
Setting Obstruction Force (level1- level9 adjustable)
If the gate meets an obstruction during closing, it will stop and reverse for 15cm~20cm.
1.
Press and hold SET until '3' indicated on the LED display, and then release the SET.
2.
Level '1' (default) will be displayed.
3.
Press OPEN to increase the obstruction force, the maximum force is level 9. Press CLOSE to
decrease force, the minimum force is level 1.
4.
Press SET to confirm and 'II' will be displayed.
Setting Auto Close (0~90 seconds adjustable)
Press and hold OPEN until '─' is indicated on the LED display.
1.
2.
'0' Second (default) will be displayed.
3.
Set timer to '0', the automatic close function will be disabled.
4.
Press OPEN to increase the auto close time (1-10seconds, 2-20seconds...9-90seconds), press
CLOSE to decrease time.
5.
Press SET to confirm the setting. 'II' will be displayed.
NOTE: Automatic close function is available only when the door is in fully opened position.

Remote Control

1.
The remote control works in a single channel mode. It has four buttons.
2.
The function of button 1, button 2 and button4 are the same. With each press of the remote
control button which has been programmed, the gate will close, stop, open or stop cycle.
Adding Extra Transmitter (LEARN)
1.
Press and hold CODE, '.' will be indicated on the LED display.
2.
Press any key on transmitter (button 1, 2, 3, 4) twice.
3.
'.' on the LED display will flash then turn off.
4.
The learning process is finished.
5.
Up to 40 transmitters can be added.
Erase Transmitter
Press and hold the CODE button on control board until '.' turns on and then turns off. This indicates
that all the transmitters have been erased completely.

Setting Pedestrian Mode

1.
Press and hold SET, release the SET when '4' appears on the LED display.
2.
'1' (default) will be displayed.
3.
Press OPEN to increase the width of pedestrian mode (1-70cm, 2-75cm...9-110cm), press
CLOSE to decrease width.
4.
Press SET to confirm the setting.
5.
External Pedestrian Mode Key can be connected to control the pedestrian mode.

Setting Auto-close Time of Pedestrian Mode

1.
Press and hold SET, The LED will display number from '1' to '5', release the SET when the
number '5' appears on the LED display.
2.
Number '0' (default) appears on the LED display.
3.
Set timer to '0', the automatic close function of pedestrian mode is disabled.
4.
Press OPEN to increase the auto-close time of pedestrian mode (1-5 seconds, 2-10
seconds...9-45 seconds), press CLOSE to decrease time.
5.
Press SET to confirm the setting.
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents