SETTING ADJUSTMENT
DELAY IN TIME: It is recommended to change the delay in time for
flush valves for urinals or toilets only.
If required, the delay intime can also be modified in taps as follows:
Press the IN button. Wait until a quick flashing of the red light of the
sensor eye is perceived. Then, press +to increase the delay in time and
- to reduce it.
DELAY OUT TIME: This button allows modifying the water flow
time after the user removes his hands from the tap. A delay out time
close to 0 will save more water. An increased delay out time will make
the user experience more comfortable.
If required, the delay out time can be modified as follows: Press the
OUT button. Wait until a quick flashing of the red light of the sensor
eye is perceived. Then, press +to increase the delay out time and - to
reduce it.
TEMPORARY OFF FUNCTION: This function is ideal to perform
any kind of activity in front of the sensor without operating the
system (for example, cleaning). The tap will remain shut for 1 minute
when this button is pressed once. To cancel this function and to return
to normal operation press the On/Off button again or wait 1 minute.
RESET BUTTON: This function restores al the factory settings
except for the sensor range. If required, press the Reset button and
without releasing it, press the +button once.
Note: To enter the self adjusting mode, use the ADJ button.