2. Set the network type of SOCKET A1 to TCPC (TCP Client), target IP as 192.168.4.100. local port as 0(random port),
target port 8886, click Save.
3. Open the CAN analyzer software, select the correct COM port and baud rate, and connect the device to TCP Server
for communication test with "network debugging assistant"
The below picture shows a standard data frame sent by the network. The CAN sending ID is 0x00 0x00 0x00 0x00 0x01
and the data is 0X11 0x22 0x33 0x44 0x55. The data sent should conform to the data format (see the basic function of
CAN-Data Protocol for details).

2.4.3. TCP Server instruction

1. Set the Network Debugging Assistant to TCP Client, set the remote host IP to 192.168.4.101, and set the remote
host port number to 8886.