Start-up procedure

When the air supply is connected, the device can be connected to the power supply. For this purpose
first plug the 24V plug into the power supply socket (3) of the ozonizer. Then insert the IEC power
cord of the power adapter into the power supply. Only when this is done, plug the safety plug into the
socket.
The following guide values for setting the ozone volume apply: approx. 10 mg of ozone per hour for
100 ml sea water; approx. 10 mg of ozone per hour for 200 litres of fresh water.
To determine the ozone requirements, we recommend measuring the redox potential with a Sander
redox measuring and regulating device, which switches the ozonizer on and off automatically
depending on the set target value..
 "Sander ORP Measurement and Controller device for 12VDC devices", Type No. 7.1C
When the device is new, we recommend gradually increasing the output over a period of roughly 14
days. This allows the living organisms in the water to slowly adjust to the improved water quality.

Operation with a "Sander Redox measurement and control unit"

Remove the plug from the socket (4) and replace it
with the adapter for connecting a Sander Redox
measurement device.
Next, connect the two plugs with the "Sander Redox
measurement and control device (see instructions
of the device).
The actual value and the switching status are
displayed on the redox meter.
8
Revision status 23.05.2016