Malfunctions

Fault Air Volume
The air flow is less 50l/h. The device shuts off and is thus protected
against overheating.
Then check air supply, eliminating any blockages.
Temperature fault (> 70°C)
Cause of overheating: Insufficient ventilation (example: a closed
technical cabinet) leads to less air flowing through the device during
a maximum performance setting. The ozonizer stops. It will start up
automatically after cooling down.
Fault High Voltage
The ozone output can be reduced or interrupted through the ingress
of water or dirt particles.
Switch off the ozonizer and disconnect the mains plug Blow air
through to remove water seepage.
Clean of the ozone element (see "Cleaning procedure").
If such impairments cannot be rectified by cleaning the device,
please contact your specialist dealer or send the device directly to
the manufacturer.