Cleaning And Maintenance Of The Ozone Element - Sander XT 2000 Instruction Manual

Ozonizer
Hide thumbs Also See for XT 2000:
Table of Contents

Advertisement

Cleaning and maintenance of the ozone element

The ozone output is reduced considerably with high humidity and dust. Therefore an ozone element
(4) has been developed that can be easily opened and cleaned if necessary.
. If the device is in permanent use, we recommend checking the ozone element every three to six
weeks for dirt particles..
Before cleaning the ozone generator let it run for a few minutes without ozone to have the ozone
element ozone free
Procedure when cleaning:
 Switch off the ozone generator (Press Start/Stop button
 Allow the connection plate (7) to cool down
 Unplug the power supply unit
 Remove the power plug (3) from the ozonizer
 Remove the tubes from the tube connections
 Unscrew locking screws (2) of the connection plate (7) using a commercial hexagon socket
wrench
 Remove cover from the connection plate (7)
 Clean the ceramic plates using a cloth and warm water (and standard cream cleanser, if
necessary); when doing so, also remove any dirt from the connection nipples
 Allow the device to dry thoroughly
Assembly and switching on again:
 Place the connection plate (7) in position, making sure that the sealing ring is firmly seated in
the groove
 Reinsert the Allen screws (2) and then crosswise tighten them evenly by hand
 Connect the hoses to the hose connections
 Plug the 24V plug into the power socket (3)
 Plug the wall power supply unit back into the socket.
 Switch on ozone generator (press Start/Stop button