Download Print this page

Technical Information; Installation Considerations - Hans Grohe 15460181 Installation/User Instructions/Warranty

Advertisement

Tools Required / Outiles Utiles /
Herramientas Útiles
22 mm
2" / 52 mm
¼" / 6 mm
2
English

Technical Information

Recommended water pressure
Max. water pressure
Recommended hot water temp.
Max. hot water temp
Flow rate @ 44 PSI
Max. depth of mounting surface
*Please know and follow all applicable local plumbing
codes when setting the temperature on the water heater.

Installation Considerations

• For best results, Hansgrohe recommends that this
unit be installed by a licensed, professional plumber.
• Please read over these instructions thoroughly
before beginning installation. Make sure that you
have all tools and supplies needed to complete the
installation.
• This unit requires ½" hot and cold supply lines (not
included)
• To insure correct operation of the thermostatic
mixing valve, the hot and cold water supplies MUST
be connected to the correct inlets.
• This unit includes a cutout template, which
must be used.
• This unit must be completed with a trim kit. The
handshower must be installed.
• Protection against back siphonage is provided by
a check valve (included with the trim kit) and by
an automatically resetting diverter (included with
the trim kit).
• To insure proper fit of the trim, the surface material
(tile, etc) must be installed prior to installation of this
rough.
• Keep this booklet and the receipt (or other proof
of date and place of purchase) for this product in
a safe place. The receipt is required should it be
necessary to request warranty parts.
15 - 75 PSI
145 PSI
120° - 140° F*
176°F*
approx. 5.8 GPM
1"

Advertisement

loading