To set a Crescendo B sequence, turn the ROTARY DIAL to select step 1. Adjust the stops
to a suitable registration for step 1. (Note: You can play the organ at any time to hear your
selected registration) Press and hold the SET piston, then while holding SET press the
MEMORY button in the Console Controller. "DONE!!" will briefly flash on the first line of
the display to indicate the step has been programmed. Release both the SET piston and
MEMORY button. Step 1 is now programmed. Repeat the above procedure to set all
available crescendo step positions.
Important! DO NOT USE THE CRESCENDO SHOE TO MOVE BETWEEN STEPS
WHILE PROGRAMMING CRESCENDO B STEP POSITIONS. Crescendo B data in other
step positions will cause the current stop registration on the stopboard to change, i.e. a blank
step position would turn all stops off or another subsequent step position with data (not yet re-
programmed) will change the current stop registration on the stopboard. When programming
Crescendo steps always use the ROTARY DIAL to move between steps.
To copy the current Crescendo step's stop registration to another step, use the ROTARY
DIAL on the Console Controller to select a different step. Press and hold the SET piston,
then while holding SET press the MEMORY button on the Console Controller. The display
will briefly flash the word "DONE!!" on the first line. Release both the SET piston and
MEMORY button. The previous step has now been copied to the step position indicated in
the display.
Editing A Crescendo B Sequence
Advance to the 'CRESC/TUTTI B' window function (see section A-2).
To enter the
"SHOW" mode, press the CURSOR button until the flashing cursor is positioned on the
mode name in the Console Controller. Turn the ROTARY DIAL until the word "SHOW"
appears in the display. Press the CURSOR button until the flashing cursor is positioned on
the word "step" in the display. As before, the display will indicate which step is currently
activated. Use the ROTARY DIAL to move through the step positions one by one while
observing the stops/controls. The stops/controls will change accordingly as to which step
position is currently active.
To make a change to a step position you must re-enter the "SET" mode by pressing the
CURSOR button until the flashing cursor is positioned on the mode name "SHOW". Turn
the ROTARY DIAL until the word "SET" appears in the display.
Note: The step position indicator will remain at the current step position that was selected in
"SHOW mode. Adjust the stop registration for that step.
Important: DO NOT MOVE THE CRESCENDO SHOE AT THIS TIME.
Once changes to the registration are complete, save the step by pressing and holding the SET
piston. Then, while holding SET press the MEMORY button in the Console Controller.
The display will briefly flash the word "DONE!!" on the first line. Release both the SET
piston and MEMORY button. The step is now saved to the step position indicated in the
display. To continue viewing steps you must return to "SHOW" mode by pressing the
CURSOR button until the flashing cursor is positioned on the word "step" in the display.
Turn the ROTARY DIAL to view additional crescendo steps.