RD5100H O+ Operation Manual Section 1 Preface Before you begin WARNING: Direct connection to live conductors is Thank you for your interest in Radiodetection’s POTENTIALLY LETHAL. Direct connections to live RD5100™H conductors should be attempted by fully qualified O+ cable and pipe locator. personnel only using the relevant products that allow The RD5100H O+ delivers the latest in locating...
RD5100H O+ Operation Manual Section 2 Introduction carried out at least once a year either at Radiodetection’s 2.1 About this manual service center or an approved Radiodetection service This manual provides cable and pipe survey center. Alternatively eCert may be used to validate the professionals with comprehensive operating instructions calibration of the RD5100H O+ locator.
RD5100H O+ Operation Manual Follow your company and national safety procedures and an audio source and use only the minimum level, or requirements when operating this equipment in any necessary to take your measurements. Excessive environment or workplace. If you are unsure what exposure to loud sounds can cause hearing damage.
RD5100H O+ Operation Manual 25 Output power level: Displays the output power in watts or as a percentage. 3.2 RD5100H O+ transmitter 26 Resistance measurements: Displays the resistance or current in Direct Connection mode. Transmitter features 27 Alphanumeric description of selected operation LCD.
Page 11
RD5100H O+ Operation Manual Locator menu options Use the keys to scroll through the submenu options. Table 3.1: Locator menu options Press the key to confirm selection and return to the previous level or exit the menu. Adjust the speaker volume from 0 (mute) to 3 (loudest).
RD5100H O+ Operation Manual Section 4 Operation 4.1 First use Power options RD5100H O+ systems are shipped as standard configured to use non rechargeable D-cell alkaline batteries. Both the locator and transmitter can also be powered using good quality rechargeable D-cell NiMH batteries. In addition the locator and transmitter can be powered respectively by optional accessory NiMH and Li-Ion rechargeable battery packs.
Page 13
RD5100H O+ Operation Manual If using a Li-Ion battery pack un-plug the lead clicks on both sides, then close the battery pack. connector (Refer to Figure 4.7). Lift the accessory cover slightly and press the battery retaining latch inwards. Figure 4.6: Installing a new battery pack If using the Li-ion battery pack, plug the lead into the battery connector (Refer to Figure 4.7).
Page 14
RD5100H O+ Operation Manual Figure 4.10: Press the release catch and lift the battery pack away Figure 4.8: Release then remove the accessory tray Turn the release catch, then open the battery compartment. Release the retaining catch (Refer to Figure 4.10) by pressing gently, then lift the battery pack away.
RD5100H O+ Operation Manual 4.3 Keypad actions & shortcuts Locator key actions Table 4.1 - Locator key actions Short press Long press Enter the menu Switch power off Scroll through locate frequencies from low to high When using active frequencies: Turn Target Position Indicator (TPI) Figure 4.12 - Charging the locator Li-ion battery pack...
RD5100H O+ Operation Manual Refer to the locator and transmitter menu options (Table Transmitter key actions 3.2) for more information. Table 4.2 - Transmitter key actions NOTE: These procedures refer to both the transmitter and locator unless stated otherwise. Short press Long press Before changing settings, ensure the locator or Enter the menu...
RD5100H O+ Operation Manual Power network frequency Press the key to accept your selection and return to the main menu. Locator units are available to purchase with either 50Hz or 60Hz. This parameter is not customer configurable. Press the key to return to the main operation screen.
RD5100H O+ Operation Manual StrikeAlert (‘ALERT’) menu and setting StrikeAlert to To configure boost: OFF. Press the key to enter the menu. StrikeAlert can also be disabled using the RD5100 Manager PC software. Refer to the RD5100 Manager Scroll to the BOOST menu using the keys.
RD5100H O+ Operation Manual To enable or disable Eco mode. 2. Hold down the key until MEAS is displayed and the measuring icon is activated. Press the key to enter the menu The transmitter display will now indicate the voltage Scroll to the BATT menu using the keys level measured across the connection leads.
RD5100H O+ Operation Manual Section 5 Locating cables and pipes This section introduces the principals and techniques of locating buried cable and pipe utilities with the RD5100H system. For more information on the theory of cable and pipe location, refer to ABC & XYZ of locating buried pipes and cables, which is available to download from www.radiodetection.com 5.1 Frequencies...
RD5100H O+ Operation Manual Guidance mode offers good performance in distorted WARNING: Before applying or removing the clamp fields and provides three indicators to guide the user around a power cable, ensure that the clamp is towards the target line. connected to the transmitter at all times.
RD5100H O+ Operation Manual To select Peak mode: Radio. Adjust the sensitivity to maximum; reduce the Press the key to select either Power or Radio sensitivity to keep the bar graph on scale when there is a response. mode. The Peak mode icon is displayed on the Traverse the area in a grid search, at a steady walk, LCD.
Page 23
RD5100H O+ Operation Manual The second person holds the locator at the start of the area to be searched and with the locator at right angles to the probable direction of the buried lines. Set the locator sensitivity level as high as possible without the locator picking up any airborne signals directly from the transmitter.
RD5100H O+ Operation Manual Section 6 Depth and current readings east and west) is relative to the active frequency signal detected by the locator. 6.1 TruDepth™ When locating lines, make sure the Compass display is The RD5100H O+ locator provides automatic in the north-south orientation position.
RD5100H O+ Operation Manual Select the same frequency as is selected on the 6.2 Verifying depth transmitter but make sure that this frequency is in the measurements sonde mode. Check a suspect or critical depth reading by lifting the Move the locator from left to right and when the locator 50mm (2”) above the ground and repeating the bargraph reading is at its Peak note the depth as measurement.
Page 26
RD5100H O+ Operation Manual Figure 6.3 - Current readings In congested areas, where there is more than one line, the locator may sometimes detect a stronger signal from an adjacent line to which the signal has coupled or shares common grounding because it is nearer the surface.
Page 27
RD5100H O+ Operation Manual Because current measurement is a function of depth, it is Applying a transmitter signal only available in active locating modes. The transmitter signal can be connected, clamped or induced to the target line in the same way as the signal for line tracing is applied.
RD5100H O+ Operation Manual Section 7 Locating techniques 7.1 Identifying target utilities Choose a signal application point where the line is furthest from other lines and not in a congested area Induction When using single-ended connection, site the ground stake as far from the target line as possible If several conductors are running in parallel, and it is not and away from other buried lines...
RD5100H O+ Operation Manual Metal railings Metal fence posts. 7.2 Signal & ground connection 7.3 Double-ended connections Large diameter water pipes and gas distribution pipes Manhole covers that are laid in sections sometimes have insulated joints between the sections and can be difficult to locate using Sometimes when locating, it is not possible to insert the a single ended connect.
RD5100H O+ Operation Manual Section 8 Using accessories 8.1 About accessories The clamp may buzz or vibrate if it is placed around a power cable that has significant net current flow. This is The transmitter is compatible with a range of normal and does not harm the equipment.
RD5100H O+ Operation Manual pipes, to the 33kHz Super Sonde, which with a depth range of 15m (50ft) targets deep sewer pipes. Consult the precision locate accessory range brochure or web page on www.radiodetection.com for a full list of all available sondes and their technical specifications.
Page 32
RD5100H O+ Operation Manual indicate a clear Peak response directly over the sonde. Propel the sonde a further 1 or 2m, pinpoint, and Locator sensitivity is now set for tracing the duct or drain mark the position. Repeat this pinpoint procedure at unless the distance between sonde and locator changes.
Page 33
RD5100H O+ Operation Manual becoming too hot to touch, resulting in risk of personal injury and damage to the equipment. The FlexiTrace can be used in two modes: Sonde mode or Line mode. In sonde mode only the tip of the FlexiTrace is energized whilst in line mode its whole length is energized.
RD5100H O+ Operation Manual Section 9 Current Direction (CD) 9.1 Understanding CD Current Direction recognition is a feature that helps to positively identify a line at points distant from the application of the signal. It is highly desirable, if not essential, for positive identification of long distance lines.
RD5100H O+ Operation Manual Performing a CD reset 9.2 CD reset You should perform a CD reset every time you select a About CD reset CD frequency. CD reset can only be performed when in CD mode. When you trace a signal on very long target lines, the transmitter signal gradually bleeds into the ground by To perform a CD reset: capacitance.
RD5100H O+ Operation Manual Section 10 Bluetooth wireless connections RD5100H2O+ locators feature a Bluetooth wireless module, as standard, providing the ability to connect to iLOC enabled transmitters such as RD5100H2O+ Tx. Press the key to switch Bluetooth off and return to the NOTE: The RD5100H2O+ locator wireless features may previous menu be subject to national and or local regulations.
RD5100H O+ Operation Manual persistent Bluetooth icon for the duration of the 10.5 Troubleshooting connection. Successful wireless communication depends on a number If pairing fails, ensure that any nearby Bluetooth devices factors including: battery life, electromagnetic are switched off or invisible then repeat the process. interference, device memory and physical obstructions.
Page 38
RD5100H O+ Operation Manual Bluetooth error codes If an error occurs when attempting to perform any Bluetooth command using the locator to the transmitter or the locator to a PC or PDA, the LCD will display a code to help you resolve the problem on the locator. The codes are as follows: BT Code Description...
Section 11 iLOC iLOC is a standard feature of the RD5100H2O+ locator 11.2 iLOC functions and transmitter. iLOC lets you control the transmitter remotely using your locator. With iLOC you can adjust the output frequency, power settings and use Changing frequencies SideStep™.
transmitter and retry the procedure. If the connection HIGH: High power output continues to fail, return to the transmitter and reset the BOOST: Temporarily boosts transmitter power connection using the procedure described in Section output to its maximum level 12.7 Once you have selected the mode you want, press key to confirm...
RD5100H O+ Operation Manual Section 12 Appendices required by law) that they are serviced at least once a 12.1 Care and maintenance year, either at Radiodetection or a Radiodetection- The RD5100H O+ locator and transmitter are robust, approved repair center. durable and weatherproof.
RD5100H O+ Operation Manual You can use RD5100 Manager to register your products NOTE: To upgrade your software you need to have to extend the warranty to a total of 3 years (see Section created an account using RD5100 Manager and have a 12.4), setup your locator by performing a number of live internet connection.
RD5100H O+ Operation Manual 12.7 List of supported accessories RD5100H2O+ Locator Accessories Image Part number Headphones 10/RX-HEADPHONES RD5100H2O+ Transmitter Accessories Image Part number 10/TX-LPC-XX Live Plug Connector XX= US, UK, EU Live Cable Connector (with Crocodile clips) 10/TX-LCC 2" (50mm) Transmitter Signal Clamp 10/TX-CLAMP-50 4"...
Page 44
RD5100H O+ Operation Manual Accessories for tracing or locating non-conductive utilities Standard Sonde 33kHz, depth up to 5m 10/SONDE-STD-33 Standard Sonde 8kHz, depth up to 5m 10/SONDE-STD-8 Standard Sonde 512Hz, depth up to 5m 10/SONDE-STD-512 Standard Sonde 512Hz single end, depth up to 5m 10/SONDE-STD-512-TW Sewer Sonde 33kHz, depth up to 8m 10/SONDE-SEWER-33...
Page 45
RD5100H O+ Operation Manual Power options RD5100H2O+ Locator accessories Li-Ion rechargeable battery pack in gr. grey (no charger) 10/RX51-BATPACK-LION (4 pins) 10/RX51-2DCELL-TRAY 2 cells battery tray (2x D-Cell / LR20) 10/RX-ACHARGER-LION Li-Ion 12V automotive charger Li-Ion mains charger (includes power lead) 10/RX-MCHARGER-LION-XX 10/RX51-ABATPACK-LION Li-Ion rechargeable battery pack with auto charger...
RD5100H O+ Operation Manual Transport and Storage Accessories RD5100H2O+ Locator accessories Locator & transmitter universal, soft carry bag 10/LOCATORBAG RD5100H2O+ flight, hard case 10/RD7K8KCASE US Hard case 10/RD7K8KCASE-USA Calibration Certificates, Remote Calibration and PC Software eCert™ Calibration Credit 10/RX-ECERT RD5100Manager™ Visit www.radiodetection.com/rdmanager Check product documentation for details Warranty Registration (for free software upgrades)