Summary of Contents for SPX C.A.T4

  • Page 1 U S E r G U I d E C.A.T4 and Genny4 ™ ™ 9 0 / U G 0 9 2 E N G / 0 5 I S S U E 5 0 9 / 2 0 1 4...
  • Page 2 C.A.T4 and Genny4.       locate Regularly check your C.A.T4 and Genny4, in all modes, Power signal over a cable which gives a response you are familiar with.     ...
  • Page 3 Genny4 provides a second locate signal alongside the 33kHz signal Depth / Warning readout SWING indicator which can be located by C.A.T4 to assist in locating smaller cables Signal Strength and spurs. Previous C.A.T models are not designed to locate this bargraph signal.
  • Page 4 Switch on the Genny4 and set the C.A.T4 to Genny mode to locate from above ground. Connections can be made to any metallic part of the buried cable.
  • Page 5 Move at least 10m away and use the C.A.T to scan for pipes and cables (see ‘Locating with C.A.T4’). for logging system errors. If a problem is detected the unit will...
  • Page 6 Hold the C.A.T4 with the blade vertical and with the lower edge just CALSafe enabled units are equipped with a system which does not above the ground. Do not swing the C.A.T4 or tilt it more than a permit them to function once they are beyond the expected service/ few degrees from the vertical.
  • Page 7 An initial sweep using Avoidance Mode is recommended, followed by detailed scans using the other modes. Use the Genny mode for Depth estimation once a pipe or cable has been detected (C.A.T4+, eC.A.T4+ and gC.A.T4+ only). Active search using Induction – finding parallel pipes...
  • Page 8 In this situation C.A.T4 can be expected to locate the interference that may otherwise overload the C.A.T’s electronics.
  • Page 9 UTI LITI E S lifting the C.A.T4 to bring it out of the overloaded condition or use the C.A.T4 in a different location. The Mouse is a small self-...
  • Page 10 Genny mode. NOTE: The Live Plug Connector provides protection to 250V AC. Locate the main Mouse signal as previously described. Hold the C.A.T4 vertical and in line with the Mouse. Press and hold the depth Service and Maintenance button until ‘...
  • Page 11 To run an eCert test, the C.A.T4 should be connected to an internet- C.A.T4 and Genny4 products are manufactured in the U.K. under enabled PC on which the C.A.T Manager software is installed. ISO9001 certified conditions. Additional purchase may be required contact Radiodetection for more details.
  • Page 12 Neglect e.g. opening of cases where there are no user replaceable parts. © 2014 Radiodetection Ltd. All rights reserved. Radiodetection is a subsidiary of SPX Corporation. C.A.T, Accidents, fire, liquids, chemicals, other substances, flooding, Genny, StrikeAlert, C.A.T Manager, eCert, CALSafe and Radiodetection are trademarks of Radiodetection vibrations, excessive heat, improper ventilation, power are either trademarks of Radiodetection in the United States and/or other countries.
  • Page 13 Tel: +44 (0) 117 976 7776 Fax: +44 (0) 117 976 7775 rd.sales.uk@spx.com www.radiodetection.com Radiodetection (France) 13 Grande Rue, 76220, Neuf Marché, France Tel: +33 (0) 2 32 89 93 60 Fax: +33 (0) 2 35 90 95 58 rd.sales.fr@spx.com http://fr.radiodetection.com Radiodetection (Benelux) Industriestraat 11, 7041 GD ’ s -Heerenberg, Netherlands Tel: +31 (0) 314 66 47 00 Fax: +31 (0) 314 66 41 30 rd.sales.nl@spx.com http://nl.radiodetection.com...